The dzhileks automation unit does not turn off the reason. Where to call the emergency service to call the master at the house of the Nabbat Rostov Bataysk. Optimal pressure inside the hydraulic tank

  • extend the life of the pump;

General working principle:

When choosing automation for a pump, consider the following specifications:

  • connecting dimensions in inches;
  • power consumption;
  • network voltage;
  • degree of protection;
  • the highest water flow rate (liters per minute);
  • maximum withstand pressure;
  • temperature range of the working environment.

Specifications Description

Without pumping units not bypassing any network autonomous water supply. They create the required pressure, providing fluid supply to the points of water intake. However, the use of water will become really convenient only if there is automation for the pump. This function block will output the water management quality to new level. As a result, the operation of the equipment will be optimized.

High-tech and functional automation:

  • extend the life of the pump;
  • will start and turn it off depending on the pressure of the liquid in the pipeline;
  • protect the pumping group from "dry running";
  • minimize the number of emergencies;
  • provide automatic maintenance required technological parameters;
  • will increase the comfort of system management (the user will no longer have to constantly monitor the operation of the equipment).

The device and principle of operation of automation for the pump

Exist different means automation for pumps, among which are dry-running blockers, water pressure switches, electronic components, sensors, etc. As a rule, electronics operate in conjunction with additional equipment (hydraulic accumulator, float switch, etc.). In this case, the adjustment of the operation of the pumping group can be performed both in terms of pressure and flow. An important constituent element is a pressure gauge that provides visual control of the parameters of the water supply network.

Today, there are several generations of automation for pumps. Newest electronic devices are considered the most efficient due to high-tech equipment, advanced functionality and finer settings.

General working principle:

  • when the pressure drops, the unit independently starts the pumping unit (in particular, this happens when the valves are opened);
  • in the absence of water flow, the electric pump is turned off (all taps are closed);
  • automatic shutdown of the pump group can also occur if the liquid flow is not high enough (protection against "dry running").

The specifics of the choice and installation of automation for the pump

Mounting automation unit performed in a vertical position in any place located between the pump and the first point of water distribution (faucet). In this case, the outlet pipe is connected to the pipeline, and the inlet pipe is connected to the outlet fitting of the electric pump.

  • all hydraulic connections must be tight, the pressure gauge is fastened through the sealing ring;
  • if a pump with a working pressure exceeding the limit is used allowed values, a pressure reducer is installed at the inlet to the unit;
  • with a high current strength, a magnetic starter is additionally mounted;
  • for electrical connection, the circuit shown on the casing of the circuit board is activated;
  • before the first start, the suction pipe and the electric pump are filled with water, and only then is it connected to the network;
  • strictly follow the safety requirements provided by the manufacturer - this will ensure stable operation of the system, protect against injuries and emergencies, and retain the right to warranty service.

When choosing automation for a pump, consider the following specifications.

/ Automation unit for the pump

We offer for sale modern automation units for pumps manufactured by Gileks. Before you buy automatic device We invite you to familiarize yourself with its characteristics.

The automation unit (automatic device) allows you to automate the operation of the electric pump, start it when the pressure drops (when the tap is opened) and stop it when the water flow in the water supply system stops (when the tap is closed). In addition, the automation unit provides protection for the pump from running without water ("dry running").

The automation unit is designed for pumping clean water that does not contain solid particles. In the presence of solid particles, it is necessary to install a filter at the inlet to the automation unit. The presence of a pressure gauge provides visual control of the pressure in the water supply system.

Operating principle

The automation unit starts the electric pump within 20-25 seconds after connecting to the mains. Subsequent starts of the electric pump occur when the starting pressure is reached, under the influence of opening the valve. In contrast to systems with a pressure-tank switch, the condition for stopping the electric pump is not dictated by the achievement of a certain pressure in the system, but is determined by a decrease in flow to minimum values. As soon as the automation unit detects this condition, it stops the electric pump with a delay of 7 + 15 seconds, the timing logic is aimed at reducing the frequency of operation of the electric pump in low flow conditions.

The automation unit can be used in conjunction with


Mounting

1. The pressure gauge can be mounted on one of the two sides of the automation unit, using an O-ring and two mounting screws. Choosing a convenient location for the pressure gauge, with opposite side plug the hole with a screw without using any seal. Install the automation unit in a strictly vertical position at any point located between the pump supply and the first draw-off point (faucet) so that the inlet ( external thread 1") was connected to the direction of the water flow outlet from the pump, and the side outlet (male thread 1") corresponded to the direction of flow in the pipeline. Make sure it's completely sealed hydraulic connections. In case of using an electric pump with a maximum pressure of more than 10 bar, it is necessary to install a pressure reducer at the inlet to the automation unit.

2. Follow the wiring diagram on the circuit board cover for the electrical connection. When using an automation unit with three-phase or single-phase electric pumps with a switching current of more than 10 A, use an electromagnetic starter. You must use an electrical cable with thermal resistance not lower than 99 ° C.

3. Starting set pressure is set to 1.5 bar, which is the optimum value for most applications. This value can be changed using the adjusting screw located on the top of the automation unit marked "+" and "-".

Starting the automation unit

ATTENTION: If the level of water to be filled is lower than the level at which the pump is installed, you should without fail use bottom check valve on the suction pipe.

1. Before commissioning, completely fill the suction pipe and the electric pump with water and start the latter, thereby supplying power to the “NETWORK” automation unit. After stopping the electric pump, open the valve located at the highest point.

2. The installation is correct if the electric pump runs continuously and there is a regular flow of water at the outlet of the faucet. If there is no water flow, it is possible to extend the operation of the electric pump by holding down the "RESET" button for a period longer than the timing of the automation unit. If, in this case, there is no flow, turn off the power to the electric pump and repeat the procedure starting from point 1.

Dry code protection

The red indicator "PROTECTION" lights up when the electric pump is turned off, signaling the danger of dry running. After making sure that the suction line is filled with water, start the electric pump by pressing the "RESET" button.

Specifications

Voltage - 230-240 V 50/60 Hz
Maximum switching current - 10 (6) A
Starting pressure - 1.5 + 3.5 atm.
Maximum water flow - 80 l/min
The maximum allowable pressure is 10 atm.
Maximum water temperature - 60°C
Mounting dimensions - 1"
Degree of protection - 1Р65

ATTENTION:
The non-return valve located between the electric pump and the automation unit, as well as after the automation unit, can cause incorrect operation of the automation unit itself.
Starting pressure adjustment must be carried out by competent personnel in compliance with all safety standards.
This operation is aimed at changing the starting pressure of turning on the electric pump.
The shutdown pressure of the automation unit is not adjustable and corresponds to the maximum pressure created by the electric pump.

If broken a water pump or an automatic water supply pumping station - do not be discouraged and do not worry! Unplug the pump, find your phone and dial our number:

Confirmed compliance with high standards.

The Chinese also gave us a certificate of conformity. We can not only install and maintain certain Chinese equipment, but also issue an opinion service center about the cause of equipment failure. The Chinese are to blame, or perhaps the Russians.

Inga wrote on 29.01.2018 at 08:50

I am from Rostov, the second time I contact this company and the second time they help out, despite the bad weather and weekends. And I’m also glad that they think through everything to the smallest detail, and when you say the brand of the pump, they take with them all possible spare parts for it. Great rarity now such a thoughtful approach. By the way, in Rostov in the SC Screwdriver, I was “fought” for half a day on Friday, waiting for a call, and then they offered to postpone the repair to Monday. And then the master came on Saturday morning and did everything. Thanks

We will arrive at a convenient time for you, find the problem and fix the problem.

If the water pressure is low

If the water on the first floor flows at least somehow, and on the second it flows very weakly

If a cold water goes well, but barely hot

We know how to fix it! And most likely for this you do not need to buy a new expensive pump! Or new house. First you need to contact the service center.

If the pump hums but does not pump

If the pump is noisy

If you just don't like something

Call and just talk to our specialist. Tell us about the problem. It happens that half an hour is enough to fix a malfunction, and people endure inconvenience for years!

We have a good electrician. There is good plumber. installer assembler pumping equipment. Pump repairman and pumping station. Master driller of water wells. There is no problem for which there is no solution!

We can: repair water pump, pump station, pool pump. Replace submersible submersible pump in a well up to 120 meters deep. Set up automatic pump control. Cottage, high-rise building, office building- irrelevant. Do I need to change circulation pump, or install a pump to increase water pressure in a private house and apartment - professionally, quickly and inexpensively, NaBBaT employees will do it

Our service will not upset or tire you. If you bring the pump in for repair yourself.

An initial inspection, in order to identify the main malfunction, can be carried out in the presence of the client. If the repair of the pumping station takes no more than an hour and the necessary components are available, we will do it immediately upon contact. This is usually what happens.

If your Grundfos pump(Model matters) Repair in one hour is not guaranteed. Many spare parts only under the order. After the initial diagnosis, if it is clear that we will not immediately do the client leaves the pump and according to the availability of spare parts we will repair, check and call.

Usually two or three days Grundfos back in line.
And so, we repair almost everything. Availability lathe and an experienced turner allow for non-standard repairs of expensive pumps. Let's restore seats under the bearings and the stuffing box, grind the shaft, For example!

What to do if it is impossible to fix the malfunction of the pumping station on site. We arrived at the facility on call and see that the pump was brought to a state of necessity overhaul and it can only be repaired qualitatively in a workshop.
we will do ALL FOR YOU
we will dismantle and deliver the pump to the workshop, repair it, deliver it and install it in place, perform the connection of the pumping station and the necessary commissioning.
This service is for wealthy clients.


You can bring a pump for a well to our service center for the repair of pumping stations from 9 a.m. to 8 p.m. at the address: Bataysk-Zapadny (Koysug), st. Armavirskaya 29 or Armavir lane 29. On different maps one place has a different name. Call ahead! We can be out.

If an automatic water supply pumping station for a house has worked for more than four years in a damp basement or in a "pit" on the street, then it technical condition determines the replacement of many components. This is a hydraulic accumulator, which has become a rusty "piece of iron", this is flexible eyeliner threatening to flood any room, and a pressure switch with burnt contacts and a clogged hole. Plus, a complete disassembly of the engine to replace bearings and mechanical seals, stuffing box. Repair will cost the cost of a new pumping station! Why is this repaired?

We will select a new pumping station for you with the appropriate parameters. There are always some of the best pumping stations available, at a price below the market!

If the client decides to buy a pumping station from us or submersible pump, we will take the product out of the box in the presence of the buyer, install the “purchase” on the stand and check it in test mode!

This is a gift from the company. You don't have to pay for this!

What other gifts are provided for our dear customers?

We won't leave you without water! The water supply system will be promptly restored and the pressure in the taps will correspond to SNiP 2.04.02-84 clause 2.26. The minimum free pressure in the water supply network of the settlement with the maximum household and drinking water consumption at the entrance to the building above the ground should be taken for a one-story building at least 10 m, with a larger number of storeys, 4 m should be added to each floor.

And is it free too?

Almost free! The departure of the emergency team is paid according to the current price list and for October 2019 is:

Calling the master in the city of Bataysk at a convenient time for the master - 1300 rubles

Calling the master in the city of Bataysk at a convenient time for the client (7:00 - 22:00) - 3200 rubles

Departure of the master to others settlements Rostov region at a convenient time for the master - 1600 rubles + 19 rubles / km intercity

Departure of the master to other settlements of the Rostov region at a time convenient for the client (7:00 - 22:00) - 3800 rubles + 19 rubles / km intercity

What are the duties of the called master of the emergency brigade?
Approximately the same thing that is included in the duties of ambulance doctors - if possible, do not let the patient die!
In our case, repair, adjustment, maintenance of pumping equipment installed by the client, without changing spare parts! Usually, with timely maintenance, this is enough! An honest competent master will not change anything! If necessary replacement of spare parts and accessories "on the spot" be made for an additional fee in agreement with the customer and is NOT INCLUDED IN THE PRICE OF CALLING THE MASTER!
Global restructuring of the water supply system IS NOT INCLUDED IN THE COST OF CALLING THE MASTER of the emergency team!
For alteration, restructuring, improvement of the water supply system at the facility, the visiting specialist will draw up separate estimate and after agreement with the customer, similar work will be carried out!

Lonely pensioners, large families— discount gifts and special conditions for the performance of works from the NaBBAT service center

If you have any questions, please specify from 8:00 to 20:00 by phone:

Also, the Chinese gave us a certificate of compliance with their high requirements for the diagnosis, installation and repair of 4WATER pumping equipment.

We guarantee the maximum desire to do our work in accordance with the norms of Christian morality and in the shortest time. When you re-apply to our company, a guaranteed 10% discount on the work carried out. Upon completion of the work, the customer is obliged to check the quality of the work performed and has the right to control the progress of the work performed (video filming to help him) and, if everything is fine, sign the act of acceptance of the work performed. Additional guarantees and wishes of the customer are negotiated and prescribed in the acceptance certificate.

We offer for sale modern automation units for pumps manufactured by Gileks. Before you buy an automatic device, we suggest that you familiarize yourself with its characteristics.


The automation unit (automatic device) allows you to automate the operation of the electric pump, start it when the pressure drops (when the tap is opened) and stop it when the water flow in the water supply system stops (when the tap is closed). In addition, the automation unit provides protection for the pump from running without water (“dry running”).

The automation unit is designed for pumping clean water that does not contain solid particles. In the presence of solid particles, it is necessary to install a filter at the inlet to the automation unit. The presence of a pressure gauge provides visual control of the pressure in the water supply system.

Operating principle

The automation unit starts the electric pump within 20-25 seconds after connecting to the mains. Subsequent starts of the electric pump occur when the starting pressure is reached, under the influence of opening the valve. In contrast to systems with a pressure-tank switch, the condition for stopping the electric pump is not dictated by the achievement of a certain pressure in the system, but is determined by a decrease in flow to minimum values. As soon as the automation unit detects this condition, it stops the electric pump with a delay of 7 + 15 seconds, the timing logic is aimed at reducing the frequency of operation of the electric pump in low flow conditions.

The automation unit can be used in conjunction with the pressure switch RDM-5

Mounting

1. The pressure gauge can be mounted on one of the two sides of the automation unit, using an O-ring and two mounting screws. Having chosen a convenient position for the pressure gauge, plug the hole on the opposite side with a screw without using any seal. Install the automation unit in a strictly vertical position at any point located between the pump supply and the first tap (faucet) so that the inlet (male thread 1 ″) is connected to the direction of the water flow from the pump, and the side outlet (male thread 1″) corresponded to the direction of flow in the pipeline. Make sure the hydraulic connections are completely tight. In case of using an electric pump with a maximum pressure of more than 10 bar, it is necessary to install a pressure reducer at the inlet to the automation unit.

2. Follow the wiring diagram on the circuit board cover for the electrical connection. When using an automation unit with three-phase or single-phase electric pumps with a switching current of more than 10 A, use an electromagnetic starter. It is necessary to use an electrical cable with a thermal resistance of at least 99°C.

3. Starting set pressure is set to 1.5 bar, which is the optimum value for most applications. This value can be changed using the adjusting screw located on the top of the automation unit marked "+" and "-".

Starting the automation unit

ATTENTION: If the level of water to be filled is lower than the level at which the pump is installed, it is mandatory to use a foot check valve on the suction pipe.

1. Before commissioning, completely fill the suction pipe and the electric pump with water and start the latter, thereby supplying power to the “NETWORK” automation unit. After stopping the electric pump, open the valve located at the highest point.

2. The installation is correct if the electric pump runs continuously and there is a regular flow of water at the outlet of the faucet. If there is no water flow, it is possible to extend the operation of the electric pump by holding down the "RESET" button for a period longer than the timing of the automation unit. If, in this case, there is no flow, turn off the power to the electric pump and repeat the procedure starting from point 1.

Dry code protection

The red indicator "PROTECTION" lights up when the electric pump is turned off, signaling the danger of dry running. After making sure that the suction line is filled with water, start the electric pump by pressing the "RESET" button.

www.agrovodcom.ru

1 Total pump automation

The Gileks Crab automation unit is a device that automates the operation of an electric pump. It turns on the system when the pressure drops (the valve opens), and turns it off when the flow stops (the valve closes). Automation also lies in the protection of the pumping station during its "simple" operation - without water, on a "dry run".


The automatic Gilex block only applies to clean water that does not contain solids. If the latter are available, then a filter element must be purchased separately for the automation unit. And if you mount a pressure gauge, then pressure control can be carried out visually.
to the menu

1.1 How does it work?

The Gileks 9001 automatic unit turns on 30 seconds after connecting to the mains. It then turns off and goes into sleep mode. Further activation of the device occurs when the pressure changes - opening and closing the valve.

As soon as the pressure drops to the minimum allowable rate, the control element of the automation will turn off the pump. So the safety and performance of the device is significantly extended.

After the pressure drops to the minimum allowable level, the system will not turn off immediately, but after several tens of seconds (usually from five to twenty, depending on the specific model). The pump shutdown delay is needed in order to weak pressure water, he systematically did not turn off. This allows you to extend the life of the system.
to the menu

1.2 Block Automation Jelex (Dzhileks): consider the insides (video)


to the menu

1.3 Installation

To automate the control of the pump, you need to purchase the appropriate additional components for it (depending on your needs), and connect them in the following sequence:

  1. The pressure gauge is attached to the automatic unit from the side using the fasteners included in the kit. Which side to mount - "a matter of discretion." But, it is important to carefully fix the device on the panel, without using sealing elements.
  2. The automation unit is mounted exclusively in a vertical position. It can also be attached to any convenient location, but on the segment between the tap (the first water intake point) and the pump supply system. Moreover, it must be done in such a way that the outer inlet of the system is adjacent to the water outlet channel from the pump, and the side outlet is adjacent to the water flow in the pipe.
  3. All connections must be tightly fixed. It is worth making sure that they are tight and double-check the correct connection of all connecting elements.
  4. If a automatic equipment is used for electric pumping systems with a maximum pressure threshold of 15 bar, then a pressure reducer is mounted at the input of the automation.
  5. The body of the device (or circuit board) contains wiring diagram automation connections. Strictly follow it when connecting! If a single or three-phase pump with an operating current of more than 10 Amperes is used, the automation must be connected through an electromagnetic starter. The cable used to connect the device must be resistant to elevated temperatures (above 100 degrees) and non-flammable.

  6. Automatic adjustment and the operation of systems (minimum pressure) is designed for a pressure of 2 atm. This option is the most common and optimal for most systems. But, this parameter can be easily adjusted if necessary. This is done by rotating the crane, which is located on top. automatic system, and has plus and minus markers.

1.4 Starting the automatic system

Important! When the level incoming water below the level at which it is mounted pumping system, it is imperative to mount a bottom check valve on the inlet pipe.

We start the automation as follows:

  1. Immediately before turning on the device, we completely fill the inlet pipe of the pump with water and start it (the "Network" LED should light up). This manipulation will turn on the automation unit. As soon as the pump starts to work and, after a while, stops, you need to open the outlet valve, which is located at the highest point.
  2. If the pump runs all the time with the tap open, and provides a continuous flow of water, the installation is considered correct. The lack of water flow indicates that you need to hold down the "Restart" button and keep it for the duration of the automatic system. If the flow is still missing during such manipulation, you need to repeat the launch.

1.5 No-load protection

When the “Protection” LED lights up on the automation unit, and the pump itself is turned off, this may indicate a danger idle work systems. This is how press control works.

Recheck all systems again. If everything is in order - let the water out of the incoming system, and fill it again. Then click the "Reboot" button.
to the menu

2 Optimum characteristics of automation for pumps

Vibrating or any other type of pump can be additionally equipped with automation systems. But, they have different parameters, properties, etc. Which ones are worth buying?

Technical indicators (optimal):

  • Operating voltage = 210-250 V;
  • Frequency = 40/70 Hz;
  • Minimum operating pressure= 1-4 atm.;
  • Load current = 6-10 A;
  • Water flow rate = 70-100 l/min;
  • Upper pressure threshold = 15 atm.;
  • Maximum water temperature = 75 degrees;
  • Diameter inlet pipe= 1 inch;
  • Degree of protection = 1P65.

2.1 What do you need to know?

Important! The valve located on the pipe section between the automatic / pumping systems, and the valve running on the outlet pipe of the automatic unit, are the culprits in equipment malfunctions.

The minimum working pressure of the equipment cannot be changed independently. This should be done by electricians who have experience, are familiar with regulatory documentation and comply with safety standards.


The maximum working pressure is not regulated by automation. It corresponds to the indicator of the electric pump.

nasosovnet.ru

Principle of operation

Despite the fact that the relay regulates the pressure of the water pressure, its mechanisms include electrical components. Under water pressure, two contacts are closed, so the connection to the mains is carried out:

  • when the pressure is below the set upper pressure limit, the relay contacts remain closed, the pump continues to pump water;
  • when the pressure exceeds the upper pressure limit, the contacts open, the pump stops working.

The principle of operation is not complicated, but consumers have some difficulties when adjusting the pressure switch, setting the lower and upper limits.

Adjustment Method

The setting of the pressure switch by the manufacturers in the factories is not always accurate or not suitable for local operating conditions. But the design is made in such a way that each owner adjusts the necessary parameters without any problems. In private houses, pumps at the water supply point in front of the accumulator must create a head pressure of at least 1.4 atmospheres. Otherwise, the adjustment does not make sense, the contacts will not close and the pump will not turn on. There must be a pressure gauge at the connection point, according to its readings, the pressure value is judged:

Scheme of connecting the relay to the expansion tank

  • We connect the pressure switch to the receiving point, as required by the instructions, the accumulator is not connected, a plug is installed instead. The pump is connected to the network - this way the operation of the relay is checked at the factory settings and the tightness of the network to the relay.
  • Record the pressure gauge readings (3 atmospheres).
  • Remove the housing cover from the relay.
Screws for adjusting the pressure limits under the housing cover

Under the housing cover there are large and small nuts with springs, when the large nut is rotated clockwise, the fixing spring is compressed, the upper limit increases. The upper limit is reduced by turning the large nut counterclockwise.

  • Adjust the pump shutdown moment with a large nut, the best option is 2.5–3 atmospheres, take 2.8.
  • Check the pressure in the accumulator, it should have a separate pressure gauge, let's assume that it is 1.5 atm. Connect expansion tank to the relay.
  • Open the tap at the highest point of the water supply, if the pressure is not enough, pump up with a bicycle pump to expansion tank to the required pressure.
  • Having opened the water, observe at what value of the pressure gauge the relay will turn on the pump. Record the lower limit reading when the pump turns on with a drop in head. Let's assume that this value will be 1 atmosphere.
  • 2.8–1 - the difference between the lower and upper limits will be 1.8 atm., This is 0.3 atmospheres more than the pressure in the expansion tank.

The operating manual specifies that the pressure of the lower limit should ideally be 0.2 atmospheres higher than the pressure in the expansion tank. With this installation ratio, the number of starts for the electric pump is optimal, which significantly extends the service life of the pump and relay. The difference can be corrected with a small bolt with a spring or by changing the pressure in the accumulator, pump or bleed air. Correctly installed relays pressure RDM 5 "Dzhileks" will make the pump mode more economical, reduce power consumption and last a long time.

domelectrik.ru

What functions does the device perform?

In private houses where there is no running water, the issue of providing drinking quality water is solved in 2 ways:

  • installation of a tank or arrangement of a pool filled with imported water;
  • drilling a well to an aquifer.

Water supply to the house is carried out using a pump required power. But the magnitude of the water pressure during its operation is too high to connect the pump unit to the internal water supply networks directly. Therefore, an intermediate container with a membrane is installed in the house - a hydraulic accumulator, and required pressure the network supports the RDM 5 pressure switch. The device allows you to automate the process of supplying water to autonomous systems ah water supply.

Operating principle

The device consists of a brass body with fittings for connection to water supply network, spring valves and electrical relay. Outside, the elements are covered with a plastic cover. The scheme of operation of the pressure switch RDM 5 is as follows:

  1. The manufacturer sets the device to the lowest pressure limit of 1.4 bar, the highest - 2.8 bar. When the pressure in the accumulator is less than the lower limit, the relay contacts are closed, and the pump pumps water into the intermediate membrane tank.
  2. When the pressure has risen to the upper limit (2.8 bar), the spring valve and opens the relay contacts. The water supply is stopped.
  3. When a water intake appears in the house, the accumulator starts to empty, the pressure decreases, and when the lower threshold of 1.4 bar is reached, the relay contacts close again and the pump resumes its operation.

As a rule, the RDM 5 device is equipped with ready-made pumping stations, consisting of a pump, a water accumulator tank and the control relay itself. The station is set up at the factory and is completely ready for operation, all that remains is to connect it to the pipe and the mains. But finished products are not suitable for everyone for the following reasons:

  • the capacity of the accumulator is insufficient;
  • the pressure of the regular pump is small to ensure the supply of water to required height;
  • a downhole pump is used, lowered into the well.

In these cases, the automatic water supply system will have to be assembled from individual elements, and set the pressure switch accordingly, coordinating its operation with the storage tank. Before purchasing and connecting the device, it is recommended to study its technical characteristics:

  • pressure control range in the water supply system - from 1 to 4.6 bar;
  • ambient temperature range — from 0 to +40 °С;
  • minimum pressure drop - 1 bar;
  • supply voltage - 220 V;
  • fitting diameter - DN 15, connection - G ¼''.

If for any of specifications relay RDM 5 does not suit you, you will have to look for another regulator. But practice shows that the parameters of this device meet the requirements of the vast majority of autonomous water supply systems.

How to adjust the device?

The pressure switch is configured after the installation of the internal and external water supply network of the house and connection to electrical network.

Connections for outdoor and internal pipelines must be checked by tests so that subsequent leakage does not interfere with the adjustment process. Due to leaky joints, the pressure before or after the pump will spontaneously decrease, which will also affect the operation of the relay.

Before setting, determine the required head pressure. To supply water to all points of water intake located on different floors, it is necessary to provide the necessary pressure in the accumulator. The efforts of the tank membrane should be enough to push the entire volume of water to the required height and overcome all local resistance. At home, this pressure value is most often determined experimentally.

The calculation is simple: 1 m of lifting height is equal to 10 m of horizontal section and corresponds to a pressure of 0.1 bar. The farthest branch of the water supply is taken into account. Having roughly determined the required pressure, it is necessary to create such pressure from the air chamber of the accumulator. To do this, remove the plastic cap from the spool (usually located at the end of the tank) and pump up the air chamber with a conventional automobile pump, controlling the pressure with a pressure gauge.

  1. Without connecting the branch pipe of the internal water supply network, check how the relay works in conjunction with the pump at the factory settings. At the same time, check the tightness of the outer pipeline.
  2. Remove the plastic relay cover covering the adjusting screws.
  3. The large screw regulates the upper limit (pump shutdown), the small screw regulates the pressure drop. Adjust the lower limit so that its value is 0.2 bar more than you pumped into the accumulator.
  4. To get out on exact values, you will have to adjust several times by opening the taps of the mixers and releasing water from the battery. At the same time, record the pressure gauge readings when the pump is turned off and on and correct them with adjusting screws.

As a result of the settings, the difference between the lower and upper limit should not be less than 1 bar. Practice shows that the optimal pressure drop is about 1.5 bar, then the pump will not turn on too often. At the end of the adjustment, do not rush to put the cover back in place, follow the operation of the system for 1 day. It may need a little adjustment.

pikucha.ru

1 Features of the company control unit

The main element of automation of the company's pumping process is the Gileks automation unit. Such a device is connected directly to the pumping apparatus and reacts to the pressure level in the system.

The Jilex block consists of a plastic case with a metal lid. Inside the housing there is a spring, an electronic unit equipped with a pressure switch and a movable mechanism that closes the contacts when the pressure drops. For external control for the operation of the device in side surface block has a built-in pressure gauge.

The device is designed to work on the basis of a pumping station or other surface pump that pumps clean water. Use with a low content of abrasive impurities is also possible, but in this case the device is equipped with an additional filter.
to the menu

1.1 How the instrument works

Automation Gileks operates autonomously from a conventional electrical network. After 30 seconds after installing and connecting the unit, it turns on and works for a few seconds. Further, the device turns off and is activated only in the event of a change in pressure in the line.

When the tap at the point of water consumption is opened, the pressure in the pipe begins to decrease rapidly. In this case, the unit immediately turns on and, when the minimum pressure is reached, activates the electric pump. The appliance pumps water until the pressure equalizes again (when the tap closes). After the tap is closed, the device works for another 5-20 seconds, continuing to pump water into the line. Such a measure is a precaution in case the pressure in the system drops below normal and the device is not able to track the pressure level.
to the menu

1.2 JELEX AUTOMATIC UNIT (JILEKS): WE CONSIDER THE INSIDE (VIDEO)


to the menu

2 Correct installation of the device

Automation Dzhileks 9001 is installed in the supply line complete with additional equipment. So milestone is an correct installation and setup of all components. Installation of the pressure control automation unit from Gileks is carried out in the following order:

  1. First of all, if a modification is purchased without measuring instruments, you should purchase a pressure gauge and install it on the side panel. The mechanism is necessary to control and manage the block.
  2. Myself automatic apparatus crashes into the water main in the area between the water consumption point (faucet) and the pumping device. The unit is installed exclusively in a vertical position, with the blue metal cover up. In this case, the inlet of the device (indicated in the instructions) should be located on the side of the pump outlet. The outlet port conducts the water further into the supply line.
  3. After the control apparatus is mounted in line, it is necessary to carefully inspect all joints and connections for tightness. If errors are found during installation, they should be sealed with sealant or connecting elements.
  4. The unit is connected to the network strictly according to the scheme specified in the instructions. Moreover, if the device is equipped with a pump with a current of more than 10 amperes, a magnetic starter is additionally installed. The main requirement for the electrical cable used with the device is increased resistance to high temperatures.

If necessary, the supply line is supplemented with filters for water purification and a receiver for equalizing pressure in the system.

After all the components are mounted in the trunk, it is necessary to check the device. To do this, the pump inlet through the pipeline is filled with liquid and the pump is turned on. One of the indicators on the unit immediately lights up. This indicates that there is contact between the unit and the pumping unit. The device works for several tens of seconds and then turns off.

After the device is turned off, it is necessary to open one of the taps (if there are multilevel ones, then preferably the top one). There are two options for this:

  1. In the first case, water will flow from the tap in a continuous, uninterrupted flow. The block turns on and pumping device works throughout the entire period of use of the crane. In this case, the installation of the device is correct.
  2. If the water flow is not stable or does not exist at all, you can try to restart the device with the "Restart" button. The button is pressed and held until the pumping device works. If nothing has changed in this case, the close examination device and the entire line, and, if necessary, dismantling and adjustment.

3 Pump units compatible with the unit

Automation from Gileks is a universal device. With its help, the operation of pumping devices can be regulated from various manufacturers. Regarding the principle of operation, such a pressure equalization mechanism is installed on a vibration, centrifugal, vortex, screw pump.

The device works most effectively in combination with pumping devices that meet the following characteristics:

  • current strength in the range of 6-10 A;
  • device productivity up to 100 l/min;
  • voltage not higher than 250 V;
  • the maximum temperature limit of the pumped liquid is 75 degrees;
  • connection to a pipe with a section of 1 inch.

4 Other options for automation Gileks

In addition to the automation unit, the company also produces less popular automation options for pumping equipment. One of these options is the installation of Gilex Crab. The device is responsible for stable pressure in the supply line, starts and stops the pump if necessary. In addition, the filter element cleans the flow from solids.

Gilex Crab consists of the following components:

  • polymer hydraulic distributor;
  • tank receiver with a volume of 24 or 50 liters, covered with anti-corrosion enamel;
  • electric pressure switch;
  • filter co replacement cartridge, responsible for cleaning the water stream from impurities;
  • manometer;
  • two electrical cables;
  • special bracket for fixing the unit to the wall.

The device operates on the basis of a standard 220 V electrical network. Suitable for connecting 2-3 water intake points at the same time. adjustable relay allows you to set the pressure level that the device will maintain before starting work. Like the previous type of devices, Crab 50 is a universal device and is suitable for connection to borehole pumps any manufacturer.
to the menu

4.1 Pressure switch RDM-5

More simple option automation of a pumping station is the installation of a special relay RDM-5 on it. The compact device is mounted in the line and connected to the pumping apparatus using electric cable. The wire is fixed to the relay contacts.

The principle of operation of the device is as follows. The device reacts to the level of pressure in the line. If the indicator is below the set value, the contacts are connected, the current is supplied to the water intake point and the liquid fills the pipeline until the pressure returns to normal. When the pressure level returns to normal (this indicator is also set by the user), the contacts diverge. The power supply to the downhole tool is interrupted and it turns off.

The minimum and maximum indicators at which the pumping device is triggered are set by the user. You can adjust them using two nuts that fix the degree of spring tension. A larger nut, when rotated counterclockwise, sets the maximum pressure indicator, a smaller nut, when rotated, allows you to adjust the difference between the maximum and minimum pressure.

RDM-5 is designed for use exclusively in water. The operating voltage for the device is 220-230 V. The temperature of the pumped liquid is 0-40 degrees. The relay is fixed to the pipeline with a section of ¼ inch. A prerequisite when using RDM-5 is a high-quality grounding.
to the menu

4.2 Float switch Gileks

For drainage, fecal and surface pumps for water, the cheapest and most practical way to automate is the float switch. According to the scope of use, such devices are divided into light and heavy. Drainage models are equipped with a light float, heavy floats are installed at water supply stations and water pumps.

The design consists of an electric cable 3,5,8 or 10 m long and a plastic float mechanism. Inside the float there are two contacts, a shift lever and a ball that changes the position of the lever. By the number of wires, two and three-wire floats are distinguished.

In the version with two wires, they are directly connected to the float contacts. When such a mechanism rises with the water level to the designated level, the lever presses on the contacts, they close and supply energy to the pump.

In models with three wires, the ability to turn on the fence point in the extreme upper and in the extreme lower positions is supported. To do this, one wire goes to one of the contacts, and the other two wires, depending on the position, go to the second contact.

The principle of operation of such a float mechanism is that the device automatically turns on the pump when the water level rises to the set value. In the case of a two-wire device, the float, on the contrary, opens the contacts and turns off the device when the water drops below normal.

byreniepro.ru

The device and principle of operation of automation for the pump

There are various means of automation for pumps, among which are dry-running blockers, water pressure switches, electronic components, sensors, etc. As a rule, electronics operate in conjunction with additional equipment (hydraulic accumulator, float switch, etc.). In this case, the adjustment of the operation of the pumping group can be performed both in terms of pressure and flow. An important constituent element is a pressure gauge that provides visual control of the parameters of the water supply network.

Today, there are several generations of automation for pumps. The latest electronic devices are considered the most efficient due to high-tech equipment, advanced functionality and finer settings.

General working principle:

  • when the pressure drops, the unit independently starts the pumping unit (in particular, this happens when the valves are opened);
  • in the absence of water flow, the electric pump is turned off (all taps are closed);
  • automatic shutdown of the pump group can also occur if the liquid flow is not high enough (protection against "dry running").

www.jeelex.ru

The device and principle of operation of the water pressure switch

Structurally, the relay is made in the form compact block with springs maximum and minimum pressure, the tension of which is regulated by nuts. The membrane connected to the springs reacts to changes in the pressure force. Upon reaching minimum value the spring weakens, at the maximum level it compresses more strongly. The force exerted on the springs causes the opening (closing) of the relay contacts, turning the pump off or on.

The presence of a relay in the water supply system allows you to provide a constant pressure in the system and the necessary water pressure. The pump is controlled automatically. Properly set levels of minimum and maximum pressure ensure its periodic shutdown, which contributes to a significant increase in the period of trouble-free service.

The sequence of operation of the pumping station under the control of the relay is as follows:

  • The pump pumps water into the tank.
  • The water pressure is constantly increasing, which can be tracked on the pressure gauge.
  • When the set upper pressure limit is reached, the relay is activated and turns off the pump.
  • As the water pumped into the tank is used up, the pressure decreases. When it reaches the lower level, the pump will turn on again and the cycle will repeat.

The main parameters of the relay operation:

  • Lower pressure (switch-on level). The relay contacts that turn on the pump are closed, and water enters the tank.
  • Upper pressure (off level). The relay contacts open, the pump turns off.
  • Pressure range - the difference between the two previous indicators.
  • The value of the maximum allowable shutdown pressure.

Back to content

Setting the pressure switch

In the process of assembling the pumping station Special attention is given to setting the pressure switch. The ease of operation of the water supply system, as well as the terms of the trouble-free service of all components of the device, depend on how correctly its limiting levels are set.

At the first stage, you need to check the pressure that was created in the tank during the manufacture of the pumping station. Usually, at the factory, the on-off level is set to 1.5 atmospheres, and the off level is 2.5 atmospheres. This is checked with an empty tank and the pumping station disconnected from the mains. It is recommended to check with an automotive mechanical pressure gauge. It is placed in a metal case, so the measurements are more accurate than using electronic or plastic pressure gauges. Their readings can be affected by both the air temperature in the room and the level of battery charge. It is desirable that the scale limit of the pressure gauge be as small as possible. Because on a scale of, for example, 50 atmospheres, it will be very difficult to accurately measure one atmosphere.

To check the pressure in the tank, you need to unscrew the cap that closes the spool, connect a pressure gauge and take a reading on its scale. The air pressure should continue to be checked periodically, for example once a month. In this case, water must be completely removed from the tank by turning off the pump and opening all taps.

Another option is also possible - carefully monitor the shutdown pressure of the pump. If it has increased, this will mean a decrease in air pressure in the tank. The lower the air pressure, the more water can be created. However, the pressure spread from a completely filled to a practically empty tank is large, and all this will depend on the preferences of the consumer.

Having chosen the desired mode of operation, you need to set it by bleeding excess air for this, or pump it up additionally. It must be borne in mind that one should not reduce the pressure to a value of less than one atmosphere, and also pump it too much. Due to the small amount of air, the rubber container filled with water inside the tank will touch its walls and be wiped. And excess air will not make it possible to pump in a lot of water, since a significant part of the tank volume will be occupied by air.

Back to content

Setting the pump on and off pressure levels

In pumping stations that are delivered assembled, the pressure switch is pre-configured according to best option. But when it is installed from various elements at the place of operation, the relay must be configured. This is due to the need to ensure an effective relationship between the relay settings and the volume of the tank and the pump head. In addition, it may be necessary to change the initial setting of the pressure switch. The procedure for this should be as follows:


In practice, the power of the pumps is chosen such that it does not allow pumping the tank to the extreme limit. Typically, the cut-off pressure is set a couple of atmospheres above the turn-on threshold.

It is also possible to set pressure limits that differ from the recommended values. In this way, you can set own version mode of operation of the pumping station. Moreover, when setting the pressure difference with a small nut, one must proceed from the fact that starting point the reading should be the lower level set by the large nut. You can set the upper level only within the limits for which the system is designed. In addition, rubber hoses and other plumbing also withstand pressure, not higher than the calculated one. All this must be taken into account when installing the pumping station. In addition, the excessive pressure of water from the tap is often completely unnecessary and uncomfortable.

Back to content

Pressure switch adjustment

Adjustment of the pressure switch is practiced in cases where it is necessary to set the levels of upper and lower pressures to the specified values. For example, you want to set the upper pressure to 3 atmospheres, the lower - 1.7 atmospheres. The adjustment process is as follows:

  • Turn on the pump and pump water into the tank to the pressure on the pressure gauge of 3 atmospheres.
  • Switch off the pump.
  • Open the relay cover and slowly turn the small nut until the relay operates. Turning the nut clockwise means an increase in pressure, in the opposite direction - a decrease. The upper level is set - 3 atmospheres.
  • Open the tap and drain the water from the tank to the pressure value on the pressure gauge of 1.7 atmospheres.
  • Shut off valve.
  • Open the relay cover and slowly turn the large nut until the contacts actuate. The lower level is set - 1.7 atmospheres. It should be slightly higher than the air pressure in the tank.

If asked high pressure to turn off and low - to turn on, the tank is filling up large quantity water, and there is no need to frequently turn on the pump. The inconvenience arises only because of the large pressure difference when the tank is full or almost empty. In other cases, when the pressure range is small, and the pump often has to be pumped up, the water pressure in the system is uniform and quite comfortable.

In the next article, you will learn about connecting a hydraulic accumulator to a water supply system - the most common connection schemes.