Aogv 11.6 technical characteristics borinsky. Borinsky floor gas boilers: a detailed overview of the apparatus. Model range of Borinsky gas boilers for heating

Boiler AOGV 11.6 (RK) with non-volatile automatic TGV was created at the Borinsky plant gas equipment Lipetsk and is an absolute analogue in all connecting and overall dimensions of the Gas Water Heating Apparatus (AOGV-11.6-3 Rostovgazoapparat). The gas boiler is equipped with a TGV-307 automation unit, which is made of reliable constituent parts that have proven themselves to be reliable. The control is carried out using the installed thermostat in conjunction with a solenoid valve. A thermocouple and a draft sensor are mounted in the automation system, which control the switching on and off of the device at a given temperature. The design of the boiler provides for the ignition of the pilot burner first by means of a piezoelectric element, and only after that the main burner is ignited, which is of the carob type and is more reliable and modern.

The gas heating apparatus AOGV 11.6 (RK) is perfect for replacing your round boiler manufactured by Rostov, and both pipes for connecting to the heating system are made of the same diameter Du-40, nut G1 1/2 "and have center distance 540 mm. The distance from the installation surface of the apparatus to the center of the lower branch pipe is 265 mm, which is the same as for the discontinued AOGV-11.6-3 Rostov boiler. The gas branch pipe (gas supply fitting) has DN-15 mm and G 1/2" thread, the chimney pipe supplied to the boiler must have outside diameter 112 mm and is also invariably attached to the apparatus through a cap (gravity stabilizer) supplied with the boiler.
When replacing your gas boiler with a power of 11.6 kW on AOGV 11.6 (RK) does not need to be changed project documentation and installation is quick and hassle-free.

One of the most popular for heating a private house can be called the Rostovgazoapparat AOGV 11.6 boiler. Considering not expensive components, simplicity of design and excellent reliability, these boilers have proven themselves well in operation for long years. Such a boiler is installed for heating residential premises up to 120 square meters. Inside, the water is heated using a burner, which is located at the bottom of the water tank. Gas boilers are connected to natural gas. However, if desired, you can replace the nozzles and transfer the operation of the device to liquefied gas. Boiler body and heat exchanger are made of high quality steel.

Boilers AOGV Rostov found wide application in heating residential premises and when replacing it, if you do not find a suitable analogue in terms of dimensions, connection and kilowatts, but simply purchase another boiler, in particular foreign-made, then you may encounter a number of difficulties during installation.
The cost of such gas heaters is high enough, and for correct, correct operation often needs rebuilding existing system heating of a private house. This is a replacement for cast iron or steel radiators with new aluminum ones, and replacement of the expansion tank for a new type of boiler with a pre-installed membrane. And since everything modern boilers designed to work in closed system heating with the use of forced circulation of the coolant and installation additional pump. Which can ultimately result in significant costs. Always convenient and high costs replace heating boilers with domestic analogues and save time and save yourself from unnecessary expenses for reworking heating, and even project documentation.

The design and main parts of the gas heating apparatus AOGV-11.6

Connecting dimensions of branch pipes and dimensions of AOVG-11.6 kW Borino analogue of a round boiler Rostov

Layout of the main and pilot burners in the round boiler AOGV 11.6

Specify availability information when ordering.

PURPOSE

The device is intended for heat supply of residential premises and buildings for communal purposes, equipped with water heating systems with a water column height in the water circuit of not more than 6.5 m.
The device is intended for permanent job on natural gas according to GOST 5542-87.
The device was manufactured in climatic design UHL, category 4.2 according to GOST 15150-69.

Characteristics Safety Devices
  1. Connecting dimensions to the heating system correspond to "Zhukovsky"
  2. Special heat exchanger design, application quality material:
    a) durability;
    b) high efficiency;
    c) reliability.
  3. Stainless steel burner
  4. Optimum combustion chamber
  5. Temperature control
  6. Ease of installation and maintenance
  7. Polymer staining
  8. Reliability
  9. Maintainability
  1. Temperature controller to prevent overheating of the heat exchanger
  2. Shutting off the gas supply in the event of a blackout (flame control)
  3. Shutdown in the absence of traction
  4. Wind traction stabilizer
  5. Low temperature boiler lining

 Instruction manual for the gas boiler AOGV 11.6 Eurosit (see the connection diagram in this passport of the device)


SPECIFICATIONS

Parameter or dimension name Value
AOGV- 11.6-1 AOGV-17.4-1 AOGV-23.2-1
1. Fuel Natural gas
2. Rated pressure natural gas in front of the automation unit, Pa (mm water column) 1274 (130)
Natural gas pressure range, mm.water column 65…180* 1
3. Volume content of carbon monoxide in dry undiluted natural gas combustion products, %, not more than 0,05
4. Ratio useful action device, % not less than 89
5. Coolant water
6. Coolant parameters, no more than:
0,165
- absolute pressure, MPa;
- maximum temperature, ºС 95
- carbonate hardness, mg-eq/kg, no more 0,7
- content of suspended solids absent
7. Rated thermal power automatic burner, kW (kcal/h) 11,6 (10000) 17,4 (15000) 23,2 (20000)
8. Gas inlet size:
- nominal diameter Du, mm 15 20 20
G 1/2 -B G 3/4 -B G 3/4 -B
9. Safety automation parameters
- gas supply shutdown time for
pilot and main burners, sec
- when the gas supply is interrupted or there is no
flame on the pilot burner, no more
60
- in the absence of draft in the chimney, no more no less 10
10. Vacuum in the chimney behind the apparatus, Pa from 2.94 to 29.4
mm. water. Art. 0.3 to 3.0
11. Nominal passage of water connecting pipes Du, mm 40 50 50
- thread according to GOST 6357 - 81, inch G 1 1/2 -B G2-B G2-B
12. Mass of the device, kg, no more 45 50 55
13. Heated area, m 2, no more 90 140 190
14. Capacity of the heat exchanger tank, liter 39,7 37,7 35
15. The maximum temperature of the combustion products leaving the chimney, ° С (at a gas pressure of 180 mm of water column) 130 160 210
*1 NOTE. The device is protected from emergency supply of inlet gas pressure up to 500 mm. water. Art. gas valve design.

DEVICE AND PRINCIPLE OF WORK.

The device consists of the following components and parts: a heat exchanger tank, a main burner, an ignition burner unit with a thermocouple and an ignition electrode installed in it, a combined gas valve (multifunctional regulator), a draft stabilizer, lining parts.

In the upper part of the tank - heat exchanger, a temperature controller sensor is installed, connected by a capillary tube to the thermostatic valve actuator ("bellows - thermoballoon" system), and a thermometer sensor

A design feature of the combined valve 630 EUROSIT is the presence of a device for stabilizing the outlet gas pressure, as well as combining the control of the valve in one handle with the designation of the positions by the corresponding symbols and numbers on its end face and the pointer on the valve cover. The dependence of the temperature of the heated water on the position of the control knob scale is shown below:

The principle of operation of the temperature controller is based on the expansion of the liquid when heated. The working fluid, heated in the sensor (thermoballoon) from the water in the heat exchanger tank heated by the combustion of natural gas, expands and flows through the capillary tube into the bellows, which converts the volumetric expansion into a linear movement of the mechanism that drives the system of two valves (instantaneous and dosing ). The design of the mechanism provides protection against thermal overload, which protects the "bellows - thermal bulb" system from damage and depressurization.

  1. When setting the desired water temperature in the apparatus with the control knob to increase, the instantaneous (click) valve first opens, then the dosing valve.
  2. When the water temperature in the device reaches the set value, the dosing valve is smoothly closed, switching the main burner to the "small gas" mode.
  3. When the temperature rises above the set value, an instantaneous (click) valve is activated, completely shutting off the gas to the main burner.
  4. In the absence of draft in the chimney, the exhaust gases from the furnace heat the draft sensor, the sensor is triggered by opening the normally closed contacts of the thermocouple circuit. The electromagnetic (inlet) valve closes and shuts off gas access to the main and pilot burners. The draft sensor is designed to operate during the absence of thrust for at least 10 seconds.
  5. When the gas supply from the network is interrupted, the pilot burner instantly goes out, the thermocouple cools down, the electromagnetic valve closes, blocking the gas access to the main and pilot burners. When the gas supply is resumed, the passage through the apparatus is completely blocked.
  6. When the gas pressure in the network drops below 0.65 kPa, the gas pressure on the pilot burner will also drop, the thermocouple EMF will drop to a value insufficient to hold the valve. The solenoid valve will close and cut off the gas supply to the burners.

POSITIONING AND INSTALLATION

Placement and installation of the apparatus, as well as gas supply to it, is carried out by a specialized construction and installation organization according to a project agreed with the operating enterprise (trust) gas facilities.

The room where the device is installed must have Free access outside air and ventilation hood at the ceiling.

The temperature of the room where the device is installed must not be lower than +5 ºС.

The choice of a place for the installation of the device should be made in accordance with the instructions for the safety measures set out in section 7 of this passport.

The device is installed near fireproof walls at a distance of at least 10 cm from the wall.

  1. When installing the machine near a non-combustible wall, its surface must be insulated steel sheet on an asbestos sheet with a thickness of at least 3 mm, protruding 10 cm beyond the dimensions of the case. There must be a passage at least 1 meter wide in front of the apparatus.
  2. When installing the apparatus on a combustible floor, the floor must be insulated with a steel sheet over an asbestos sheet with a thickness of at least 3 mm. The insulation should protrude 10 cm beyond the dimensions of the housing.

Before starting the installation, it is necessary to depreserve the device, check the correctness of its assembly in accordance with Fig. 1 and fig. 8 of this passport, and make sure that all parts and assembly units are securely and completely fixed.

Connect the device to the chimney, gas pipeline and pipes of the heating system. Connecting pipes pipelines must be precisely adjusted to the location inlet fittings apparatus. Connection should not be accompanied by mutual tension of pipes and units of the apparatus.

SAFETY INSTRUCTIONS

Persons who have studied this passport are allowed to service the device.

The installation and operation of the apparatus must comply with the requirements of the Rules for the Design and Safety of Operation of Hot Water Boilers, Water Heaters and Steam Boilers with Overpressure, as well as the requirements of the Safety Rules for Gas Distribution and Gas Consumption Systems. PB 12 - 529", approved by the Gosgortekhnadzor of Russia.

The operation of the devices must be carried out in accordance with the "Rules fire safety For residential buildings, hotels, hostels, buildings of administrative institutions and individual garages PPB - 01 - 03".

The operation of the device is allowed only with serviceable automatic safety and thermal control.

Gas automation security should provide:

  1. Reducing the gas supply when the water temperature reaches heating system set value.
  2. Shutdown of gas supply to the main burner when the set heating temperature is exceeded.
  3. Turning off the gas supply to the apparatus in the following cases:
    • when the gas supply to the apparatus is interrupted (for a time not exceeding 60 seconds);
    • in the absence of draft depression or in the boiler furnace (for a time not less than 10 seconds and not more than 60 seconds);
    • when the torch of the pilot burner goes out (for a time not exceeding 60 seconds).

During operation of the device, the temperature hot water must not exceed 95 °C.

It is forbidden:

  1. operate the device with the heating system partially filled with water;
  2. use other liquids as a heat carrier instead of water**;
  3. install shut-off and control valves on the supply line and the pipeline connecting the heating system with expansion tank;
  4. operate the device in case of gas leakage through the gas pipeline connections;
  5. apply open flame to detect gas leaks;
  6. operate the device in case of malfunction gas network, chimney or automation;
  7. independently troubleshoot the device;
  8. make any structural changes to the apparatus, gas pipeline and heating system.

When the device is not working, all gas taps: in front of the burner and on the gas pipeline in front of the appliance - must be in closed position(the valve handle is perpendicular to the gas pipeline).

All malfunctions during the operation of the apparatus on gas must be reported immediately. emergency service operating enterprise of the gas industry.

If gas is found in a room, immediately stop its supply, ventilate all rooms and call an emergency or repair service. Until the malfunction is eliminated, it is forbidden to light matches in the room, smoke, use

** It is allowed to use household coolant "Olga" (manufacturer: CJSC "Plant of Organic Products") according to the instructions for use. After a period of operation, the coolant must be drained and disposed of.

In the territory Russian Federation and other post-Soviet countries, old water-heating units are known. Together with them, such models as the AOGV 11 6 boiler are widespread - devices manufactured by factories in the cities of Zhukovsky and Rostov. The device runs on natural gas - the cheapest modern fuel. The boiler is unpretentious in terms of operation and maintenance.

Fuel for this unit is cheap

Features of AOGV

The abbreviation AOGV stands for simply - a gas water heating heating apparatus. The number after the letters indicates the power of the model, that is, the AOGV 116 boiler is a unit of 11.6 kW, respectively.

In technical characteristics of AOGV 11 6 3 indicates that the boiler is intended for heating a residential private house, a garage or a small utility room. The model is only shown in floor version, household units have a power in the range of 11-29 kW. The fuel used to operate the device is natural gas.

At the bottom of the boiler is a heat exchanger, under it is located gas-burner. It is she who heats the water. The unit can be converted for use liquefied gas. Steel is used to make the body of the device. High Quality. The heat exchanger is made of tubes, which ensures a high efficiency of the device.

In this video you will learn how to light the boiler AOGV 11.5

On the back there are two fittings for inlet and outlet. The top one works with a straight line, the bottom one with a reverse one. Top part the body is attached to the chimney, its diameter must exceed 12 cm. Manufacturers produce two types of boilers - single and double-circuit boilers. The latter are intended not only for heating, but also for heating water.

Distinctive characteristics of boilers

Among buyers, boilers of the Universal and Economy models are especially popular. There are significant differences in the technical characteristics of AOGV 116 of these series. The Economy version is manufactured using Russian automation; this unit can be controlled using a solenoid valve and a temperature control knob. They are connected to a thrust sensor and a thermocouple - one of the most important elements of the device.

The detail looks like a thick rod made of copper. It is necessary to control the fire on the igniter. When the draft level is lowered, the sensor is triggered, the valve at this time must shut off the natural gas supply.

Boiler AOGV 11.6 series The station wagon is produced on the basis of Italian automation. The unit is distinguished by the presence of an automatic thermostat and piezo ignition. The device can be turned on by pressing just one button, while there is no attachment to electricity networks.

There is another series of units - Comfort, it is equipped with American parts. Piezo ignition is also built into these models, but it has a different design.

Advantages and disadvantages

Among all the characteristics of the AOGV 11.6 boiler, its main advantages and disadvantages are distinguished. There are several main advantages:

  • the possibility of using natural and liquefied gas as a fuel;
  • energy independence;
  • compatibility with any system material;
  • uninterrupted work with natural and forced circulation.

The unit can be connected to any heating system. It can be made of cast iron, metal-plastic, polypropylene or steel. That is why such boilers are considered universal. There are also some disadvantages of devices:

  • the Economy series is made using obsolete parts;
  • in the event of a breakdown, it is difficult for craftsmen to find suitable parts;
  • compared to other units, this version has a rather high price.

Since Economy boilers are produced using elements made according to samples of Soviet engineers, it is very difficult to replace them during repairs. Better not to buy the most cheap options , and opt for Universal. Although in the case of buying models with imported parts, difficulties also arise, since they are not available on the domestic market. You will have to order replacement parts for damaged parts directly from the manufacturer. average cost boilers is 11-17 thousand rubles, which significantly exceeds the price of units from other manufacturers.

Distinctive feature boiler AOGV 11.6(M) is that everything connecting dimensions made exactly like a similar boiler of the Zhukovsky plant. This will allow you to easily replace the Zhukovsky boiler with the Borinsky one without additional investments and technical changes.

Buying gas boiler AOGV-11.6(M) made at the Russian plant in the Lipetsk region by skilled workers with a sober head and straight hands, you - first of all, get comfort and warmth for yourself and your family. The boilers of OAO Borinskoye do not leak or break because the management of the plant cares about the quality of its products and always meets all the standards and state standards in production.

AOGV-11.6(M) - one of the most popular among inexpensive and most importantly reliable Russian boilers, for heating rooms ranging from 40 to 90.

The AOGV-11.6(M) boiler has a security system that operates during:

  • lack of gas or traction;
  • water overheating;
  • maintaining the set temperature;

Reliable and convenient automationSitwith piezo ignition will give you a long, faithful service.

Attention! the AOGV 11.6 boiler is single-circuit and is intended only for heating your home. If using this boiler you want to have hot water supply, then you must use a double-circuit analog - boiler AKGV 11.6 (M)

Technical parameters of the boiler AOGV-11.6 (M)

Manufacturer

OAO Borinskoye Russia

Guarantee period

3 years (36 months)

Fuel

Natural gas

Automation type

EUROSIT (Italy)

Rated thermal power of the automatic burner, kW (kcal/h)

11,6 (10000)

Heated area, m²

Natural gas pressure in front of the automation unit, Pa (mm water column)

- nominal

1274 (130)

- minimum

637 (65)

- maximum

1764 (180)

Volumetric content of carbon monoxide in dry undiluted natural gas combustion products, %, no more

Efficiency of the apparatus, % not less than

coolant

Water GOST 2874-82

Heat carrier parameters, no more:

- absolute pressure, MPa

- maximum temperature, °C

- carbonate hardness, mg-eq/kg

absent

Gas connection size:

- nominal diameter Du, mm

- thread according to GOST 6357-81

G1/2-B

Security automation settings. Time to turn off the gas supply to the pilot and main burners, sec:

- when the gas supply is interrupted or there is no flame on the pilot burner, no more

- in the absence of draft in the chimney

Vacuum in the chimney behind the apparatus, Pa (mm water column)

2.94 to 29.4
(from 0.3 to 3.0)

Conditional passage of water connecting branch pipes Du, mm

thread according to GOST 6357-81

G 1 ½ - B

Heat exchanger tank capacity, l

The maximum temperature of the combustion products leaving the chimney, ° C at a gas pressure of 180 mm of water. Art.

Machine weight, kg

dimensions:

- width, mm

- depth, mm

- height, mm

Contents of delivery: