Hot water three-way boilers entroros thermotechnician tt100. Thermotechnician TT100 - hundreds of cubic meters of hot water Thermotechnician boiler with burner and heating unit

THERMOTECHNIK TT 100- three-way steel low-temperature hot water boilers gas-tube-smoke type, equipped with a furnace operating under pressurization. The boilers are designed for the production of heating hot water with a maximum temperature of 115°C at an allowable working pressure of 0.6 MPa. Boilers are used for work only in closed systems heat supply.

Application:The preferred areas of application for boilers in St. Petersburg are large heating and ventilation systems, hot water supply systems for industrial, administrative, domestic and other facilities, providing thermal energy technological equipment productions.

Design features:

Gas boilers THERMOTECHNIK TT 100 are designed as a three-pass gas-tube boiler.

The combustion chamber - the flame tube and the boiler body have a cylindrical shape. The convective heating surfaces are formed by second and third pass smoke tubes located axially symmetrically around the combustion chamber. Two-, three-row layout of second-pass fire tubes ensures high intensity of heat transfer.

The front cover of the boiler can be fully opened with the burner installed in any direction. With the front door open, convenient access to the combustion chamber and smoke tubes is provided when maintenance and boiler cleaning. At the bottom of the lid, auxiliary guides are provided to facilitate the process of closing the door.

An inspection hatch is provided in the upper part of the boiler body to inspect the fire tubes from the side of the heat carrier.

Wide annular space and large volume of water in the boiler provide the most optimal mode of operation of the boiler in the entire range of heat output.

There is a burner plate for mounting the burner on the front door. Visual control of the flame in the combustion chamber is carried out through the viewing eye.

To evenly distribute the weight load, the boiler has a solid frame base.

Continuous highly efficient thermal insulation of the boiler consists of laminated mineral wool mats 100 mm thick. The surface of the boiler is lined with corrugated aluminum coating, providing a spectacular appearance throughout the entire service life.

To move the boiler during installation and loading and unloading operations, lifting eyes are provided on the boiler body, installed symmetrically with respect to the center of mass of the boiler.

Two- and three-row layout of smoke tubes (as well as the use of heat-resistant intensifiers in the last pass flue gases for boilers with a capacity of 1 to 2.5 MW) increases the intensity of heat transfer, and, consequently, the coefficient useful action boiler.

Technical characteristics of boilers TT - 100 (1000-5000 kW)

1000 1500 2000 2500 3000 3500 4200 5000

Type of fuel


Propane-butane according to GOST 20448-90
0,6
115
60
57 86 115 143 172 200 240 287
2,9 6,6 5,3 8,3 3,8 5,2 6,4 3,7

Flue gas consumption, kg/s

0,45 0,68 0,90 1,13 1,35 1,58 1,90 2,25
0,29 0,65 0,42 0,65 0,71 1,0 0,84 1,2

Furnace volume, m3

0,692 0,793 1,390 1,500 2,260 2,520 3,440 4,270

Boiler water volume, m3

1,76 1,86 2,80 3,0 4,10 4,60 5,4 6,4
2980 3260 4680 5100 6960 7480 9400 10440

Overall dimensions WxDxH, mm

1631x
2576x
1768
1631
x2667x1768
1827s
3134x
2043
1827s
3384x
2043
2022x
3744x
2228
2001s
4144x
2228
2126x
44490x
2400

2248x
4674x
2370

Specifications boilers TT - 100 (6500-15000 kW)

Rated thermal power, kW 6500 8000 10000 12000 15000
Type of fuel Natural gas low pressure according to GOST 5542-87
Propane-butane according to GOST 20448-90
Light fuel according to GOST 305-82
Maximum overpressure of water, MPa 0,6
Maximum water temperature at the outlet of the boiler, 0С 115
Minimum water temperature at the inlet to the boiler, 0С 60
Nominal water consumption for ΔT=15K, m3/h 384 474 591 710 888
Hydraulic resistance of the water path at coolant flow rate for ΔT=15K, kPa 6,7 5,6 8,9 5,5 6,1
Flue gas consumption, kg/s 2,88 3,55 4,44 5,32 6,66
Aerodynamic resistance of the gas path for maximum power, kPa 1,06 1,14 1,44 1,4 1,74
Furnace volume, m3 5,240 6,566 8,450 10,870 13,870
Boiler water volume, m3 7,4 9,6 12,1 15,5 20
Dry boiler weight, (weight tolerance 4.5%), kg 13600 16000 19100 22100 28400
Overall dimensions WxDxH, mm 2360x
5042x
2655
2500x
5373x
2706
2640x
5945x
2859
2823x
6465x
3060
3040x
7015x
3262

The boilers are certified according to the GOST RF system and are approved for use by Rostekhnadzor of the Russian Federation
The warranty period, subject to the conditions of transportation, storage, installation and operation, is 36 months from the date of commissioning, but not more than 42 months from the date of shipment from the manufacturer.

The normative life of the boiler is 20 years (subject to the requirements and conditions of the installation and operation manual).

Boilers Termotekhnik TT100 are mass-produced. The power of boilers manufactured by Entroros varies from 1000 kW to 15000 kW. All boilers of the TT100 series have a fire-tube design of the furnace and gas ducts, belong to fire-tube type boilers and are designed for installation in boiler rooms with a maximum heat carrier temperature of up to 115 degrees C and with an operating pressure of up to 0.6 MPa. The preferred areas of application for Termotekhnik TT100 boilers are boiler rooms industrial use. These include large boiler houses of housing and communal services, boiler houses of various production facilities and boiler houses that supply thermal energy to technological equipment of various industries. Boilers Termotekhnik TT100 are used both for heating systems and for hot water supply systems (DHW).
Entroros TT100 boilers are equipped with fan-type pressurized burners that provide automatic supply, ignition and combustion of fuel. To control the burner flame in the front plate of the boiler there is a viewing eye that allows you to visually control the combustion process in the boiler furnace. Boilers Entroros Termotekhnik TT100 can be installed in a boiler room of any capacity. This is due to the wide range of boiler capacities manufactured by Entroros.

In our company, you can purchase hot-water steel fire-tube boilers of the LAVART brand, produced by the Omsk plant of innovative technologies. Go to page Boiler equipment LAVART

Models of boilers of the TT100 series:

Boilers Termotekhnik TT100-1000 with a power of 1000 kW

Hot water boilers of fire-tube type. Water consumption - 57 m³ / h. The water volume of the boiler is 1.76 m³. This boiler is the smallest boiler in the TT100 series. Maximum temperature up to 115 ºC.

Boilers Termotekhnik TT100-1500 with a power of 1500 kW

Water-heating steel gas-tube boilers. Water consumption - 86 m³ / h. The water volume of the boiler is 1.86 m³. The boiler is mass-produced and is one of the most popular Entroros boilers. Maximum temperature up to 115 ºC.

Boilers Termotekhnik TT100-2000 with a capacity of 2000 kW

Heating boilers of gas-tube-smoke type. Water consumption - 115 m³ / h. The water volume of the boiler is 2.8 m³. Coppers are made and delivered under the order. Maximum temperature up to 115 ºC.

Boilers Termotekhnik TT100-2500 with a capacity of 2500 kW

Steel three-way boilers. Water consumption - 143 m³ / h. The water volume of the boiler is 3 m³. Boilers with maximum operating power up to 2.5 MW. Maximum temperature up to 115 ºC.

Boilers Termotekhnik TT100-3000 with a power of 3000 kW

Steel boilers. Water consumption - 172 m³ / h. The water volume of the boiler is 4.1 m³. Boilers with a maximum operating power of up to 3 MW and a maximum overpressure of water up to 0.6 MPa. The maximum heat carrier temperature is up to 115 ºC.

Boilers Termotekhnik TT100-3500 with a capacity of 3500 kW

Russian industrial boilers. Water consumption - 201 m³ / h. The water volume of the boiler is 4.6 m³. Heating boilers of fire-tube design High Quality. The maximum heat carrier temperature is up to 115 ºC.

Boilers Termotekhnik TT100-4200 with a capacity of 4200 kW

Boilers high power, up to 4.2 MW. Water consumption - 241 m³ / h. The water volume of the boiler is 5.4 m³. Steel fire-tube boilers. The maximum heat carrier temperature is up to 115 ºC.

Boilers Termotekhnik TT100-5000 with a capacity of 5000 kW

Boilers Entroros Termotekhnik, industrial use. Water consumption - 287 m³ / h. The water volume of the boiler is 6.4 m³. Hot water heating boilers with high efficiency. The maximum heat carrier temperature is up to 115 ºC.

Boilers Termotekhnik TT100-6500 with a capacity of 6500 kW

Boilers TT100 of high power, manufactured by Entroros. Water consumption - 384 m³ / h. The water volume of the boiler is 7.4 m³. Hot water heating boilers with high efficiency. Maximum allowable temperature coolant at the outlet of the boiler up to 115 ºC.

Boilers Termotekhnik TT100-8000 with a capacity of 8000 kW

Boilers Termotekhnik of the TT100 series, manufactured by Entroros, with a maximum power of 8 MW. Water consumption - 474 m³ / h. The water volume of the boiler is 9.6 m³. Hot water heating boilers with high efficiency. The maximum allowable water temperature at the outlet of the boiler is up to 115 ºC.
Read more ⇒

Boilers Termotekhnik TT100-10000 with a capacity of 10000 kW

Boilers of the TT100 series, Entroros, with a maximum power of 10 MW. Water consumption - 591 m³ / h. The water volume of the boiler is 12.1 m³. Hot water heating boilers with high efficiency. The maximum water temperature at the outlet of the boiler is up to 115 ºC.
Read more ⇒

Boilers Termotekhnik TT100-12000 with a capacity of 12000 kW

Boilers TT100, with a maximum power of 12 MW. Water consumption - 688 m³ / h. The water volume of the boiler is 15.5 m³. Hot water heating boilers with high efficiency. The maximum water temperature at the outlet of the boiler is up to 115 ºC.
Read more ⇒

Boilers Termotekhnik TT100-15000 with a capacity of 15000 kW

Boilers TT100, with a maximum power of up to 15 MW. Water consumption - 888 m³ / h. The water volume of the boiler is 20 m³. Industrial hot water heating boilers with high efficiency. The maximum water temperature at the outlet of the boiler is up to 115 ºC.
Read more ⇒

All boilers Termotekhnik TT100 have a cylindrical shape of the boiler casing, combustion chamber and gas ducts. For the manufacture of the TT100 boiler, high quality steel is used, which withstands temperature loads on the internal walls of the boiler. The design of the TT100 boiler, due to the completely washed boiler wall and toruspherical bottom, provides a high intensity of heat transfer. The front wall of the boiler is mounted on hinges that are installed on the right or left side of the boiler and allow the door to be opened together with the burner. This greatly facilitates both the scheduled maintenance of the TT100 boiler and the maintenance of the burner. The design of the boiler provides for the possibility of inspecting the boiler furnace and flame tubes. To inspect the fire tubes there is an inspection hatch, which is located in the upper part of the boiler. The second hatch, intended for cleaning the flue gas collector, is located in the rear wall of the boiler. In addition, the TT100 boiler has a large annular space, which allows you to create optimal conditions for heat exchange and distribution of the coolant.

Entroros boilers Thermotechnician TT100 are supplied in various configurations. You can purchase a boiler in the minimum configuration and in the maximum. Boilers TT100 in the maximum configuration are supplied with automation, pumping groups, shutoff valves, a set of sensors, a burner and other equipment. The price of the TT100 boiler and the amount of the discount are agreed upon additionally, at the stage of preparation and discussion of the commercial offer.

In order to buy a TT100 boiler, you need to send a request to e-mail or by fax, which are listed in the "Contacts" section of the site


Not always household heating units are able to meet the thermal energy needs of large buildings. Boilers Termotekhnik TT100, TT50 and TT200 are designed for heating large areas with minimal cost.

The design of the Termotekhnik uses a special internal organization, allowing several times to increase productivity and other technical characteristics.

Why high power boilers are needed

In general, domestic heating units can effectively heat rooms up to 1000 m² in size. To increase productivity, it is necessary to connect several boilers in a cascade bundle, which is not always profitable, requires more maintenance time and often leads to excessive fuel consumption. This problem can be solved by installing an industrial steel hot water boiler Termotekhnik TT100 from Entroros.

The main purpose of the Thermotechnician station is the heating of industrial and administrative buildings large area, heating of small towns and cities. Maximum performance 5 MW. Installing a station is much more profitable than purchasing several boilers and connecting them to one network to obtain the required power.

Model overview TT100

Hot water three-way boilers Termotechnik type TT 100 are connected to the heating system closed type. In this case, the maximum heating of the coolant reaches 115 ° C, operating pressure in the pipeline 0.6 MPa. The basic package of the station includes:
  • The block of a copper - is made of the high-strength steel steady against hostile environment.
  • Burner - allows you to smoothly adjust the intensity of the flame and control temperature regime avoiding overheating and hypothermia of the premises.
  • Automation - the entire work process is controlled by a microprocessor board. It regulates the intensity of heating and gives a signal to turn off the gas supply in case of emergencies. Boiler safety automation Termotekhnik made Italian company E&M, worldwide recognized leader in the production of protection systems for heating equipment.
  • Security group- in addition to highly sensitive automation, valves and sensors are used to prevent emergencies.

A special boiler start-up program has been installed, thanks to which ignition is carried out by simply pressing a button on the control unit.

Installations differing in power

Although the TT100 station is the most popular, attention should also be paid to existing analogues that differ in power from TT50 and TT200.
  • Thermotechnician type TT50- the maximum productivity reaches 950 kW/h. The modulating burner ensures stable operation at power settings from 350 kW.
    Steel hot water heating boiler Termotekhnik TT50 is a metal cylinder, along the perimeter of which there are fire tubes of the second and third passes. Ease of use is achieved thanks to the front doors of the boiler, which provide wide access to all important components.
  • Steam industrial boiler Termotekhnik TT200- at maximum productivity provides production of 25 thousand kg. couple / hour. Economizer (purchased separately), allows you to reduce gas consumption by an average of 5%. Since the process of space heating is carried out with the help of steam, it is allowed to connect only to closed heating systems.
    The Entroros thermotechnician type TT200 steam heating boiler is equipped with an inspection hatch for visual observation of the liquid volume in the water chamber.



For safe mixing of water coming through the heating return, a special water-guiding element is installed. With its help, the heating surface is reduced and stable operation of the equipment is ensured without extreme thermal loads.

Safety is based on following the rules

The technical characteristics of Thermotechnician steam boilers significantly exceed those of conventional solid fuel equipment. But high performance is achievable only if all the rules and recommendations of the manufacturer are observed.

What should be paid attention to during installation and subsequent use of the boiler?

  • Large gas consumption- indicates heat losses or incorrect settings. Requires referral to specialists. The fuel consumption of the boiler must be within the limits established by the manufacturer (specified in technical documentation) +5%.
  • Sealing the heating system- there are high requirements regarding the installation of the heating system. Particular attention is paid to the sealing of joints and the use of high-quality heating elements that can withstand a pressure of 0.6 MPa.
  • The entire volume of the combustion chamber must be cleaned at least twice a year, before and after heating season. The presence of soot on the walls contributes to overheating of the combustion chamber and, as a result, its failure.

prevent potentially dangerous situations You can pay attention to the warning signals of automation.


Boilers TT100 from the Thermotechnik company are more profitable than conventional gas or solid fuel boilers, the savings reach 5-15%. The installation of steam equipment requires strict adherence to installation and operating regulations, as well as the cost of more quality installation heating systems. All costs pay off after the first season of operation.


Purpose:

THERMOTEHNIK ТТ100 – low-temperature three-pass steel fire-tube fire-tube boilers of various capacities (from 1000 to 15000 kW). Purpose: production of heating hot water with parameters: maximum overpressure - 0.6 MPa, maximum temperature - 115°С. The boilers operate on liquid and gaseous hydrocarbon fuels.

Well-thought-out fastening of the flame tube, combined with a large volume of boiler water and high strength guarantee long term services of boilers THERMOTECHNIK TT100. Due to the low heat density of the boiler furnace, compliance with environmental requirements is ensured. The operational efficiency of the TERMOTECHNIK TT100 boilers is facilitated by high efficiency and low hydraulic resistance.

The priority areas of application for TT100 boilers are large heating and ventilation systems, as well as hot water supply systems for various municipal and industrial facilities.


Technical description:

The TERMOTECHNIK TT100 boilers are used for the production of heating hot water only in closed heating systems.

Design

  • Gas boilers THERMOTECHNIK TT 100 are designed as three-pass gas-tube boilers.
  • The boiler body and the cylindrical flame tube form the combustion chamber. Convective heating surfaces (smoke tubes of the second and third passes) are asymmetrically located around the combustion chamber. Thanks to the 2- and 3-core arrangement of the second pass smoke tubes, a high intensity of heat transfer is ensured.
  • The design of the front cover of the boiler allows it to be fully opened with the burner installed in any direction. The open front door provides easy access to the fire tubes and combustion chamber during boiler cleaning and maintenance. Auxiliary guides are installed at the bottom of the lid, which makes it easier to close the door.
  • The inspection hatch, located in the upper part of the body on the side of the coolant, allows you to inspect the fire tubes.
  • The most optimal mode of operation of the boiler in the entire range of heat output is facilitated by a large volume of water in the boiler and a wide annulus.
  • A burner plate for mounting the burner is provided on the front door. Visual control of the flame in the combustion chamber is realized through a viewing eye.
  • A solid frame base ensures even distribution of the boiler's weight load.
  • Laminated mineral wool mats 100 mm thick form a highly effective continuous thermal insulation of the boiler. Outside, the boiler is lined with a corrugated aluminum coating.
  • Transportation and movement of the boiler during installation and handling operations is facilitated by the presence of lifting eyes on the body, installed symmetrically relative to the center of mass.
Characteristics:
Boiler size 1000 1500 2000 2500 3000 3500
1000 1500 2000 2500 3000 3500
Efficiency not less than, %92
115
60
0,6
190
hydr. resistance, kPa2,9 6,6 5,3 8,3 3,8 5,2
0,29 0,65 0,42 0,65 0,71 1,0
Boiler water volume, m31,76 1,86 2,8 3,0 4,1 4,6
57 86 115 143 172 200
2980 3260 4680 5100 6960 7480
Flue gas outlet, mm300 300 500 500 500 500
Water inlet/outlet, mm125 125 150 150 200 200
Safety valve, mm50 50 65 65 65 65
G 1/2-B
G 3/4-B
G 1/2-B
Boiler water drain, mm40 50
Condensate drain, mmG 1-B
Traction gauge, mmG 1/2-B
Boiler size 4200 5000 6500 8000 10000 12000 15000
Rated heat output, kW4200 5000 6500 8000 10000 12000 15000
Efficiency not less than, %92
Max. outlet water temperature, deg115
Min. inlet water temperature, deg60 70
Max. excess water pressure, MPa0,6
Flue gas temperature, max, deg.190
hydr. resistance, kPa6,4 3,7 2,4 3,7 7,8 3,3 4,1
Aerodynamics. resistance, kPa0,84 1,2 11 12 14,4 14 17
Boiler water volume, m35,4 6,4 7,7 9,6 12,1 15,5 20
Nominal water consumption, m3/h240 287 386 475 594 713 891
Weight of dry boiler, no more than, kg9400 10440 14000 16000 20000 24000 32000
Flue gas outlet, mm650 650 800 800 900 1000 1100
Water inlet/outlet, mm200 250 250 300 300 350 400
Safety valve, mm80 80 100 100 125 125 125
Inlet water temperature sensor, mmG 1/2-B
Outlet water temperature sensor, mmG 3/4-B
Flue gas temperature sensor, mmG 1/2-B
Boiler water drain, mm50
Condensate drain, mmG 1-B
Traction gauge, mmG 1/2-B

Documentation:

Request a Quote

Description

Boilers THERMOTECHNIK TT 100 are mass-produced in the range of rated power from 1000 kW to 5000 kW. THERMOTEHNIK TT 100 - three-way steel low-temperature water-heating boilers of gas-tube-smoke type, equipped with a furnace operating under pressurization. The boilers are designed for the production of heating hot water with a maximum temperature of 115°C at an allowable working pressure of 0.6 MPa. Boilers are used for operation only in closed heat supply systems. The preferred areas of application for the TERMOTECHNIK TT 100 boilers are large heating and ventilation systems, hot water supply systems for industrial, administrative, municipal and other facilities, providing thermal energy for production equipment. The boilers are certified according to the GOST RF system and are approved for use by Rostekhnadzor of the Russian Federation.

Peculiarities

The TT 100 boiler is designed as a gas-tube flue type boiler. The combustion chamber and the boiler body are cylindrical. Convective heating surfaces are formed by second and third pass smoke tubes located symmetrically around the combustion chamber. Two-, three-row layout of second-pass smoke tubes increases the area and intensity of heat transfer. The first rotary chamber, completely washed by water, is formed by a rear tube plate and a toruspherical bottom. The second rotary chamber is formed by the front tube plate and a specially formed lining of the front door of the boiler. The front cover can be completely folded down, or opened with the burner installed on it, as desired, to the right or left. With the front cover open, convenient access to the combustion chamber and smoke tubes is provided for maintenance and cleaning of the boiler. Inspection and cleaning of the first rotary chamber can be done through the combustion chamber. For inspection of smoke tubes from the side body of water an inspection hatch is provided in the upper part of the boiler body. The flue gas collector is cleaned through a hatch in the flue gas collection chamber of the boiler. Water inlet and outlet pipes, as well as an emergency line pipe are located on top of the boiler. Boilers TT-100 with a capacity of 2000 kW and more have two emergency line pipes. Fittings for temperature sensors are welded into the water inlet and outlet pipes. A water-guiding element is mounted under the water inlet pipe for smooth mixing of cold return water with a warm boiler. There is a burner plate for mounting the burner on the front cover. Visual control of the flame in the combustion chamber is carried out through the viewing eye. The flue gas outlet is located at the top rear wall boiler. To evenly distribute the weight load, the boiler has a frame base made of a channel. The continuous enclosing thermal insulation of the boiler consists of mineral wool mats 100 mm thick. Outside, the boiler body is sheathed with a protective casing made of aluminum sheet. For transportation of the boiler, butts are provided, welded to the upper part of the body symmetrically with respect to the center of mass of the boiler.

Specifications

Indicators TT-100 TT-100 TT-100 TT-100 TT-100 TT-100 TT-100 TT-100 TT-100
Thermal power, kW 1000 1500 2000 2500 3000 3500 4200 5000 7500
Water pressure, MPa 0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6
Outlet water temperature, °C Up to 115 Up to 115 Up to 115 Up to 115 Up to 115 Up to 115 Up to 115 Up to 115 Up to 115
Estimated fuel gas/diesel/fuel oil gas/diesel/fuel oil gas/diesel/fuel oil gas/diesel/fuel oil gas/diesel/fuel oil gas/diesel/fuel oil gas/diesel/fuel oil gas/diesel/fuel oil gas/diesel/fuel oil
Efficiency,% From 92 From 92 From 92 From 92 From 92 From 92 From 92 From 92 From 92
Dimensions (LxBxH), m 2.89x1.54 x 1.77 3.0 x 1.54 x 1.77 3.5 x 1.74 x 2.07 3.75x1.74x2.07 4.1x1.94x2.23 4.56x1.94x2.23 4.96x2.1x2.4 5.13x2.2x2.48 projected
Boiler weight, kg 2790 2950 5240 5500 6900 7900 9900 12000 projected