Thermostat TA3n - household thermostat. Temperature control modes

thermostats Italian company IMIT stamps TA3n and TA2n are used to regulate the temperature in heating systems to maintain the most comfortable temperature indoors, as well as to save electrical energy, going to heating at a time when there are no people in the room. For example, in working time it is necessary to maintain the temperature at least +20°C, and at night it is enough to maintain a temperature of +7°C in the room, which saves half of the electrical energy, and therefore saves half the money for heating every day.

Brand thermostats TA3n are practical temperature control devices that are affordable to the consumer and provide high quality regulation.

Currently thermostats (thermoregulators) TA2n are out of production and replaced by an improved model of the brand TA3n.
From the old model, he inherited ease of use and reliability. The advanced adjustment knob allows you to limit or fix the set temperature. Thermostats TA3n are presented in four modifications, which allow to obtain the most exact match to the needs of the consumer: execution with a signal lamp, with an ON/OFF switch or with a WINTER/SUMMER switch, and also without additional functions.

The operation of the TA3n thermostat is based on the expansion of saturated steam in the gas bellows.
Unlike similar devices, TA3n thermostats are highly reliable, because simple mechanical design is not prone to breakage.

Technical data of thermostats:

Contact power = 16 (2.5)A/250V~
Operating range = 5°C - 30°C
Differential =<1К
Insulation class = I
Degree of protection = IP 20
Maximum storage temperature = 50°C
Connection = 2-wire
Output = changeover contacts
Installation = on the wall
Color = white

Article code

Description

Quantity in a package, pcs.

Thermostat with function indicator and on/off switch

Thermostat with function indicator

Thermostat without additional functions

Thermostat with function indicator and WINTER/SUMMER switch

Stopper for locking the handle

on order

Basis for mounting the room thermostat on the wall on a 60 mm box. Suitable for TA3n - color black.

on order

INSTALLATION

The thermostat should be installed at a height of about 1.5 m from the floor in an area that reflects the average temperature. Avoid installation in areas with stagnant air, near doors, windows, heat sources, etc.

CONNECTION

Remove the cover by pressing the fastener "C" (see Fig. In the original passport). Fasten the thermostat to the wall with two screws with a maximum diameter of 3.5 mm using the holes (B-B) on the base of the unit.

Note: The thermostat must only be used in fixed mounting.

ELECTRICAL CONNECTIONS

Pass the wires through the hole in the base and connect them to the instrument terminals as shown in the diagram on the inside of the cover.

Attention!

Mechanical room thermostats TA2n are not currently produced and have been replaced by an improved model of the TA3n brand!

You can download the installation and use instructions for TA3 thermostats

If you have difficulty connecting thermostats, entrust their installation to our engineers.

IMIT BLUE - PROGRAMMABLE CHRONOTHERMOSTAT Thank you for choosing our products! This electronic chronothermostat allows you to program your home's heating and/or air conditioning system throughout the week, and set the desired temperature for a specific time period. The following is an instruction manual that will allow you to quickly and easily set up this unit. read it carefully and enjoy the comfort! Complies with EN 60730 - 1 and subsequent amendments EN 60730 - 2 - 7 EN 60730 - 2 - 9 Technical data – 2 alkaline batteries 1.5 type LR6 0.1°) S = 1 time per minute ɐ - 0.2 + 0.4 (@ dT / dt = 1 ° / 15 ') S - NT C 3% b SCHY - IP 20 Iɐ - II ɑ = 1K/15 min S = switching relay N = 8 (2.5)A / 250 V ~ R = 1 BU = normal environment NL L - 50° R R = 0÷ 60 ° - 6 ° (fixed) = per day / week - end / week R : - ɑ comfort temperature from 5:30 to 22:00 comfort temperature from 5:30 to 23:00 comfort temperature from 6:30 to 23:30 comfort temperature from 7:00 to 22:00 SOFTWARE class - LCD 30 min - on the wall INSTALLATION AND CONNECTION PRECAUTIONS Before connecting the chronothermostat, make sure that the supply voltage is not connected to the controlled consumer (boiler, pump, etc.) and that it corresponds to that indicated on the inside at the base of the device (250 V ~ max.) (fig.3.) at a distance of about 1.5 m from the floor, away from heat sources, doors, windows, avoid direct sunlight. (fig. 4) see figures 6 - 7 Electrical connection connect wires I I to terminal clamp n 1 and n . 2, as shown in the electrical diagram (Fig. 8). U = Nb b 1= general terminal 2=terminal n . a 3= terminal n . c. Attention: It is recommended to install the chronothermostat carefully following all safety regulations and in accordance with all regulations in force. Installing batteries When the flashing symbol appears on the display, the chronothermostat will work properly for another month, after which it will be blocked and the symbol will be constantly displayed. To replace the batteries, remove the cover with a screwdriver (fig.6). Change the cells according to the indicated direction (battery life 1 year). After changing the batteries, close the device starting from the left side (fig. 9a) and then push the cover onto the base part. (Is. 9b). Set the time settings as described in the “ɑ Z” section. SH (Fig. 1) = Display of the set program = System operation = Antifreeze active D = Reduced temperature boost belt activity E = Comfort temperature boost belt activity F = Program active SH G = Manual setting H = Reduced temperature mode I = Comfort temperature mode L = Automatic M = Cursor position for setting the program N = Empty batteries O = Hours P = Day of the week Q = Selected temperature R = Active programming S = Early operation (air conditioning) T = Early operation (heating) .2) 1 = Program setting 2 = Selecting the type of operation 3 = Selecting the "special" operation 4 = Setting the comfort temperature 5 = Setting the reduced temperature mode 6 = Exit 7 = Setting the mode / 8 = Reset button 9= Adjustment and confirmation dial CHRONOTHERMOSTAT OPERATION SETTING THE TYPE OF PROGRAMMING (daily / week - end / weekly) Remove the cover from using a screwdriver (fig.6). move the shackle to the required position (Fig. 5). - position 1 - weekly programming - position 2 - daily programming - position 3 - week-end programming When finished, close the device, starting from the left side (Fig. 9a), and then slide the cover onto the base part. (Is. 9b). press the button. SETTING THE DAY AND TIME The display shows the days of the week and the time (fig.10). Turn the knob to set the hour. To confirm, press To set the minutes, you must also turn the knob. To confirm, press then the cursor indicating the day starts flashing turn the knob to set / confirm to set the day. Press the setting/confirmation knob to confirm Note: Pressing the ESC button at any time exits the programming mode. CHANGING THE HOUR / DATE Press the button and follow the same instructions in the section “SETTING THE DAY AND TIME” (Fig. 10). SETTING THE TEMPERATURE SETTINGS To set the desired temperature when programming for a week: open the window (Fig. 2) press the comfort temperature button to change the comfort temperature settings turn the knob to set the required temperature. Press the confirmation button, or "ESC" to cancel the operation. Press the setback temperature button to change the setback temperature settings. turn the knob to set the desired temperature. Press the confirmation button, or "ESC" to cancel the operation. Note: If the required temperature is not set within 10 minutes, the chronothermostat will exit this mode and return to the previous setting. PROGRAM SETTING open the window and press the button « prog » the display will show the inscription PROG , the day and the program of the day (fig.11) by turning the knob you can program the settings for each day separately, a group of days selection of the day / group of days for programming. The display will show the set program (symbols on = comfort temperature, symbols off = reduced temperature). The display will show the setting cursor, the day of the week cursor will flash. (Is.12). SETTING / CHANGING THE PERIOD SETTINGS "comfort temperature" and "reduced temperature" mode. after the day / group of days is selected, the cursor will appear (Fig. 12). turn the setting/confirmation knob and select "beginning of period" on the timer. Press the button (comfort temperature) or (reduced temperature), each time the timer is pressed, the timer will advance by 30 minutes, activating in the program the setting made by pressing the button. eg sun button = symbol on (comfort temperature) - moon button = symbol off (low temperature mode). Example: Setting the comfort temperature period from 18:00 to 22:00. Turn the setting/confirmation knob until 18:00 Press the comfort temperature button (8x) until 22:00 Press the setting/confirmation button to confirm, or use the knob to select a new period to set it. after setting / making changes to the settings for the comfort temperature period or the setback temperature mode, press the knob to confirm the changes made or the “esc” button to cancel the changes made. Repeat the operation for other days, or for the desired group of days. After finishing programming, press "esc" to exit. FUNCTIONING ACCORDING TO THE PROGRAM (.13) Press the button until the AUTO symbol appears, the chronothermostat will work in automatic mode, according to the set program. turn the knob if it is necessary to change the temperature, the chronothermostat will maintain the set temperature until the next period change (from comfort period to setback temperature or vice versa). FUNCTIONING IN ACCORDANCE WITH MANUAL CONTROL (Fig. 14). Press the button until the symbol N appears. the set temperature corresponds to 20 º. turn the knob if you want to change the temperature. The ronothermostat will work, maintaining the manually set temperature day after day. Note: Each time the manual setting operation is exited, the set temperature is reset. When restarting the manual operation mode, the set temperature will be 20 º. FUNCTIONING OF ANTIFREEZE (Fig.15) Press the button until the symbol appears. In this mode, the room temperature will not drop below 6 º to prevent freezing of the piping system. HOLIDAY PROGRAM Press the “ F ” button until the symbol appears. turn the knob to set the date of return from vacation (for a maximum of 90 days); this will allow the chronothermostat to resume operation at ɑ at 00:01 on the set date. Press the confirmation knob, or “ esc ” to cancel. When the holiday mode is activated, the room temperature will not fall below 6 º to prevent freezing of the piping system. however, by turning the knob, you can change the set value of the “antifreeze” mode in the range from 6 to 15 º. The new setting will be active until the set period has elapsed. In order to interrupt the holiday mode, press the "esc" button. PROGRAMMING A PERIOD OF LOW TEMPERATURE MODE. Press the “F” button until the symbol appears. Turn the knob to select the end time of the period. The selected period is displayed with flashing characters. Press the knob to confirm, or “ esc ” to cancel. During this phase, the chronothermostat will operate at the temperature set in the program for the reduced temperature mode. however, it is possible to adjust the setpoint from 6 to 35º by turning the knob. The new setting will remain active until the end of the set period. To cancel the "limited setback period" mode, press the "esc" button. PROGRAMMING THE COMFORT TEMPERATURE FOR A PERIOD OF TIME Press the “F” button until the symbol appears. Turn the knob to select the end time of the period. The selected period is displayed with flashing characters. Press the knob to confirm, or “ esc ” to cancel. During this phase, the chronothermostat will operate at the comfort temperature set in the program. however, it is possible to adjust the setpoint from 6 to 35º by turning the knob. The new setting will remain active until the end of the set period. To cancel the "limited period comfort temperature mode "party" mode, press the "esc" button. RESTART THE DEVICE When you press the restart button (res) . It does not change the settings of the set program for the week. The temperature settings (reduced and comfort) are not changed. It does not reset the timer and day of the week settings. All other active functions are reset (certain programmable period, holiday programme). By pressing the reset button (r es), the device performs the “auto-test” mode, displaying all the symbols on the display for a few seconds. TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Unit does not turn on Batteries are exhausted Batteries are inserted incorrectly Wrong contact Change batteries Check correct polarity Press “ ” button System does not turn on @ Does not turn on at the set time Wrong connection Wrong program settings Antifreeze mode activated or Holiday program wrong o the actual time has been set, make sure that the wires are connected correctly to the terminals of the chrono-thermostat. Check the accuracy of the set time in the program Disable this function Check the accuracy of the day and hour, if they have been reprogrammed. make sure that the display shows the “igloo” symbol (if the device is connected to a boiler) or the “umbrella” symbol (if the device is connected to an air conditioner). The displayed temperature does not correspond to the room temperature 冷 Incorrect placement of the chronothermostat in the room. outflow of air passing from the cable duct leading to the chronothermostat. 9. Follow the instructions for placing the device. isolate the cable channel from hot or cold air flows. the display shows the symbol (11. Batteries are discharged. 11. Replace the batteries. The device does not work “correctly” 12. Batteries are not alkaline 12. Use alkaline batteries of the ﱒ type. contact a technical specialist for help www.italrussia.ru

    • Capillary pressure gauge Imit series 962/B (0...6 bar) with capillary 1500 mm. for continuous pressure measurement of liquids and gases that are neutral to metal. Connection diagram. Specifications. Language: RU | pdf 96.07 Kb

      Programmable Imit chronothermostats of the Blue series for heating and/or air-conditioning systems. User manual. Language: RU | pdf 580.07 Kb

      Imit chronothermostats of the CRX_E series with the possibility of weekly programming. User manual. Language: RU | pdf 1.76 Mb

      Capillary thermomanometer Imit series 941/B (0...120 degrees C; 0...6 bar) with 1500 mm capillaries. for continuous pressure measurement of liquids and gases that are neutral to metal. Connection diagram. Specifications. Language: RU | pdf 96.67 Kb

      Capillary thermometer Imit series 902 (0...120 degrees C) with capillary 1500 mm. for continuous pressure measurement of liquids and gases that are neutral to metal. Connection diagram. Specifications. Language: RU | pdf 64.42 Kb

      Capillary thermometer Imit series 902 (0...120 degrees C) with capillary 1000 mm. for continuous pressure measurement of liquids and gases that are neutral to metal. Connection diagram. Specifications. Language: RU | pdf 81.20 Kb

      Combined submersible thermostat Imit of the TLSC series is used in automatic control systems of boiler houses, pumps and other thermal installations for setting and maintaining the set temperature of the coolant in automatic mode and for limiting its maximum value. Connection diagram. Specifications. Language: RU | pdf 85.52 Kb

      Limit thermostat Imit of the LS1 6025 series (90/110 degrees C) with a capillary of 1000 mm. for use in safety systems of boilers, heating installations and other devices where the temperature of the coolant must not exceed the maximum value. Connection diagram. Specifications. Language: RU | pdf 115.17 Kb

      Thermostat limit Imit of the LS1 6035 series (100 C) with a capillary of 1500 mm. for use in safety systems of boilers, heating installations and other devices where the temperature of the coolant must not exceed the maximum value. Connection diagram. Specifications. Language: RU | pdf 161.33 Kb

      Thermostat limit Imit of the LS1 8025 series (130 C) with a capillary of 1000 mm. for use in safety systems of boilers, heating installations and other devices where the temperature of the coolant must not exceed the maximum value. Connection diagram. Specifications. Language: RU | pdf 173.04 Kb

      Thermostat limit Imit of the LS1 8035 series (63 degrees. With) with a capillary of 1500 mm. for use as a safety device in the exhaust system of boilers, heating installations and other devices where it is necessary to turn off the gas supply to the burner when the chimney is clogged. Connection diagram. Specifications. Language: RU | pdf 188.15 Kb

      Limit thermostat Imit of the LS1 8035 series (90/110 degrees C) with a capillary of 1500 mm. for use in safety systems of boilers, heating installations and other devices where the temperature of the coolant must not exceed the maximum value. Connection diagram. Specifications. Language: RU | pdf 172.14 Kb

      Limit thermostat Imit of the LS1 8135 series (90/110 degrees C) with a capillary of 1500 mm. for use as a safety device in non-volatile heating boilers, where the temperature of the heating medium must not exceed the set maximum value. Connection diagram. Specifications. Language: RU | pdf 98.22 Kb

      Limit thermostat Imit of the LS1 9035 series (90/110 degrees C) with a capillary of 1500 mm. for use in safety systems of boilers, heating installations and other devices where the temperature of the coolant must not exceed the maximum value. Connection diagram. Specifications. Language: RU | pdf 108.64 Kb

      Limit thermostat Imit of the LS1 9045 series (110/130 degrees C) with a capillary of 3000 mm. for use in safety systems of boilers, heating installations and other devices where the temperature of the coolant must not exceed the maximum value. Connection diagram. Specifications. Language: RU | pdf 117.37 Kb

      Limit thermostat Imit of the LS3 series (90/110 degrees C) with a capillary of 1000 mm. mainly used as a safety device in non-volatile heating boilers, where the temperature of the coolant should not exceed the set maximum value. Connection diagram. Specifications. Language: RU | pdf 89.55 Kb

      The Imit mechanical immersion thermostat of the LSC1 series with manual reset is used in heating systems to limit the maximum temperature of the coolant. Connection diagram. Specifications. Language: RU | pdf 79.71 Kb

      Thermostat adjustable Imit series TR2 9325 (0...86 degrees C) with capillary 1000 mm. It is used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 93.22 Kb

      Thermostat adjustable Imit series TR2 0325 (0...90 degrees C) with capillary 1000 mm. for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 108.17 Kb

      Thermostat adjustable Imit of the TR2 9224 series (0...210 degrees C) with a capillary of 1000 mm. for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 89.72 Kb

      Thermostat adjustable Imit TR2 9322 series (0...310 degrees C) with capillary 1000 mm. It is used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 97.24 Kb

      Thermostat adjustable Imit series TR2 9325 (0...90 degrees C) with capillary 1000 mm. It is used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 149.96 Kb

      Thermostat adjustable Imit series TR2 9328 (0...40 degrees C) with capillary 1000 mm. It is used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 134.67 Kb

      Thermostat adjustable Imit series TR2 9335 (0...87.5 degrees C) with capillary 1500 mm. It is used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 99.37 Kb

      Thermostat adjustable Imit series TR2 9335 (0...120 degrees C) with capillary 1500 mm. It is used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 96.16 Kb

      Language: RU | pdf 95.67 Kb

      Thermostat adjustable Imit series TR2 9335 (0...87 degrees C) with capillary 1500 mm. It is used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 179.29 Kb

      Thermostat adjustable Imit series TR2 9335 (0...90 degrees C) with capillary 1500 mm. It is used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 107.87 Kb

      Thermostat adjustable Imit of the TR2 9345 series (0...120 degrees C) with a capillary of 2900 mm. for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 84.13 Kb

      Thermostat adjustable Imit series TR2 9345 (0...90 degrees C) with capillary 3000 mm. for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 121.36 Kb

      Thermostat adjustable Imit series TR2 9345 (16...106 degrees C) with capillary 3000 mm. for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 142.17 Kb

      The thermostat adjustable Imit of the TRZ 3435 series 2-stage with a capillary of 1500 mm. is designed to set and maintain in automatic mode the set temperature of the heat carrier in heating boilers, air heaters and other heating installations, where a transition to operation with a reduced thermal power is provided. Connection diagram. Specifications. Language: RU | pdf 129.26 Kb

      Adjustable contact thermostat Imit of the BRC series (20...90 degrees C) is used in automatic control systems of heating installations for setting and maintaining the set temperature of the heat carrier in automatic mode. Installation instructions. The passport. Language: RU | pdf 149.02 Kb

      Adjustable contact thermostat Imit of the BRC series (20...90 degrees C) is used in automatic control systems of heating installations for setting and maintaining the set temperature of the heat carrier in automatic mode. Connection diagram. Specifications. Language: RU | pdf 67.71 Kb

      Adjustable submersible thermostat Imit of the TC2 series is used in automatic control systems of boiler houses, pumps and other installations for setting and maintaining the set temperature of the coolant in automatic mode. Connection diagram. Specifications. Language: RU | pdf 81.50 Kb

      Thermostats Imit of the TAZ series are room mechanical. Instructions for installation and operation. Language: RU | pdf 982.57 Kb

      Imit thermostats of the TAZ series are mechanical room thermostats with a signal light and an on/off switch. Connection diagram. Specifications. Language: RU | pdf 710.14 Kb

The BiLux T26 room thermostat with an air temperature sensor is an analogue of the IMIT Ta3 thermostat and is produced at the same factory in Italy. The temperature regulator has high quality of the European assembly. Equipped with LED indicator light and power switch (ON/OFF). In addition, this is a universal thermostat that can work both for heating and for cooling. Those. to it, for example, you can connect both a heater and a fan if necessary.


Despite a fairly simple connection, it happens that it raises some questions even for "specialist electricians of the 6th category" :)) who do not look at the connection diagram attached by us at all, or do not want to study it more closely.

To remove all the questions that arise during the connection process, we decided to connect the BiLux T26 thermostat ourselves the way it should be! All you have to do is do the same. And everything will work as it should!

1. We disassemble the case (according to the instructions enclosed in the box). For this it is necessary release the top latch and separate the case.

2. We connect according to the scheme:

3. When connected correctly, it should look like this:

4. After connecting the wires, assemble the case.

5. Before turning on, check that the switch lever is in the ON position. (ON)

Main functions.

  • The floor heating thermostat with a weekly program is controlled by a single-chip microcontroller.
  • High reliability. Saves energy and creates comfortable conditions in the room.
  • The device works with electric or water heating systems, starting electronic heating or activating the heating system. According to the set temperature, the thermostat automatically turns on and off the controlled object (valve, floor heater, wall heater, electric heaters, etc.).
  • Several time modes: 5 + 2, 6 + 1, 7 days, allows you to set different temperatures for weekends and / or weekdays according to six time phases. In this operating mode, the user does not need to manually change the temperature depending on the phase of the day. This will happen automatically.
  • The stylish design of the thermostat will allow you to easily fit it into the design of the room. The smooth surface of the case will facilitate the cleaning of the device.
  • All settings are saved after the power is turned off, thanks to the built-in battery.
  • The keypad lock will prevent children from accidentally changing device settings.

Technical specifications.

  • Supply voltage: 85-250VAC 50/60Hz (24V optional)
  • Operating range of the internal sensor: 0-40 o C.
  • Setting range: 5-35 o C (factory: 25 o C)
  • Internal sensor: NTC B=3380 [email protected] Celsius
  • Reading step: 0.1°C. Minimum step: 0.5°C/step
  • Maximum load power: 16A.
  • External sensor range: 0-99 o C. Setting range: 5-95 o C (factory: 50 o C)
  • External sensor:NTC B=3380 [email protected] Celsius, length 3M

User manual

Turning on and off

By pressing the button you can turn the thermostat on or off.
The display will look like this when the thermostat is off.

children lock
Press the buttons and hold for about two seconds, then the buttons will be locked. The lock icon will light up on the screen.
The lock is removed in the same way as it is set, hold the buttons pressed for two seconds.

System time
To set the system time: Press and hold the button for 5 seconds to enter the time setting mode. Press and select the parameter you want to change (day of the week / hours / minutes), press or to set the desired value of the selected parameter. To return to the previous time setting, press the button.
After setting the required minutes, press to exit the time setting mode.

Temperature control modes

The thermostat can work in three different temperature control modes, enter advanced settings to set.
Built-in sensor(IN): An internal temperature sensor is used. This mode is suitable for indoor temperature control.
External sensor (OUT): An external temperature sensor is used. This mode is suitable for floor temperature control.
Both sensors (ALL): The thermostat uses both sensors to control the temperature. This mode is suitable if you need to control the temperature in the room without overheating the floor.

Temperature display in three modes

When the thermostat is in IN mode and ALL mode. The display shows the current room temperature, as indicated by the active AIR icon.
When the thermostat is in OUT mode, FLOOR is lit. The display shows the current floor temperature measured by an external sensor.
When the thermostat is in ALL mode, press and to display the floor temperature or the location of the external sensor, and FLOOR will light up. After 5 seconds, the thermostat will automatically switch to the readings from the internal sensor and AIR will appear.

Automatic / manual mode

By pressing the button, you can select the operating mode of the thermostat, automatic or manual.
Manual mode: The thermostat automatically controls the manually set temperature until it is changed. The set temperature value is displayed below the current temperature readings and can be changed at any time using the and buttons, respectively.
Auto mode: The thermostat automatically controls the temperature at the level set by the program for the current time step, when the time for the next step comes, the system will maintain the temperature specified for it. When the thermostat is in automatic mode, the indicator lights up. inscriptions week and Stage light up on the screen alternately with an interval of 5 seconds. When on screen WEEK, the number below indicates the number of the day of the week from 1 to 7. When the screen Stage, the number below indicates the number of the active time step, from 1 to 6. Under the current temperature, the current time and the temperature set for the active time step are shown alternately in 5 second intervals.

Time step setting (thermostat programming)
Stage settings allow you to control the temperature over time automatically. Once you have set the parameters, you will not need to do anything else, the thermostat will follow the program day after day, creating comfortable conditions for you. The thermostat automatically saves all the changes you make and keeps them safe even after a power outage using the built-in battery.
The thermostat can work according to three types of schedule (5+2 / 6+1 / 7) with 6 stages. With a cycle of one week.
The beginning of each stage is the time (hours, minutes) and the temperature value that are stored in the program. The end of the current stage is the beginning of the next one.
Press and hold for 5 seconds, you will enter the time step setting interface. Numbers flashing under the inscription week indicate which type of schedule is selected (5+2 or 6+1 or 7, the default mode is 5+2, so the numbers from 1 to 5 flash). Use the button to select the parameter (Leg start time: hours, minutes and temperature for this leg) that you want to change. Use or to change the value of the selected parameter.
Example: 5+2 type schedule (5 working days + two days off) is selected. How to set the period:
Press and hold for 5 seconds, under the inscription week, the numbers from 1 to 5 will flash as in the figure on the right, set the parameters of the stages for working days P1: set the hours>minutes>temperature-> P2: set the hours>minutes>temperature -> P3: set the hours>minutes>temperature ->…- > P6: set hours>minutes>temperature. Under the inscription week the numbers 6, 7 flash.
set parameters for the holidays P1: set hours>minutes>temperature -> P2: set hours>minutes>temperature -> P3: set hours>minutes>temperature ->…-> P6: set hours>minutes>temperature. After setting last stage thermostat will go into auto mode and attaches to the execution of the specified program. Moving through the settings of time stages is carried out with the buttons and forward and backward, respectively. Setting the parameter value with the or button.
By default, the following values ​​of time steps are entered by the manufacturer:

System settings
Warning: System settings are used to set very important thermostat parameters. Only change the factory settings if you understand what you are doing.

Entering system settings: Turn off the thermostat, and then press the power button again and immediately, no longer than a second later, then press the button, the screen will appear instead of the usual numbers, which indicates a successful entry into the system settings. If a normal image appears after turning it on, repeat the login operation from the beginning.
Use the button to switch between options. Use the or button to set the required value of the selected parameter. To exit system settings scroll all the way to the end.

OFF

Image Description Setting range Default value
Temperature calibration -5°C - 5°C -2.5°C
Is used for fine tuning temperature measurements. Enter the difference between the thermostat reading and the reference temperature meter
Schedule selection 5+2/6+1/7
Set the ratio of work and weekends. You can set the working days option from Monday to Friday, from Monday to Saturday or all working days / non-working days
Anti frostbite ON:Enabled/OFF:Disabled OFF
Prevents the room temperature from falling below 0°C by turning on the heating when the temperature drops below 5°C.
Temperature control mode selection IN:Built-in OUT:External ALL:Both IN
IN:Internal sensor, room temperature OUT:External sensor, floor temperature ALL:Both sensors, room temperature control with floor temperature limitation
External sensor temperature limitation 40-80°C
Operates in ALL temperature control mode, limiting the floor temperature
Internal sensor hysteresis 0.5-4°C 1°C
The parameter value indicates how many degrees the thermostat will add to the set room temperature before it stops heating.
External sensor hysteresis 0.5-5°C 3°C
The value of the parameter indicates how many degrees the thermostat will add to the set temperature
Screen backlight operation mode
Specifies how the screen backlight will work
Action after an emergency shutdown OFF: remains switched off ON: in the state as before switching off OFF
Indicates which mode the thermostat will be in when power is restored after an emergency shutdown
Reset to factory settings Reset to factory settings

Possible malfunctions and methods for their elimination

  1. Fault phenomenon: There is no display Reason & solution:
    1^ power supply system is having problems or powjer is supplied incorrectly, please check if the inlet wire is normal.
    2^ If the connection is not right, please wired up as )