Electromechanic of diesel-electric stations. Job Description of a Diesel Technician for a Diesel Power Plant Job Description of a Technician for a Diesel Operator of a Diesel Power Plant

exceptions. On civilian ships, where the power plant consists of three or four powerful diesel generators, the position is called 1st and 2nd class motorman. A diesel or, as it is also called, a thermal power plant, regardless of the number and power of diesel-electric installations, requires round-the-clock monitoring, maintenance and routine repairs. In addition, the driver on duty monitors the change in load and its redistribution to operating generators if they operate in parallel.

Parallel operation of generators is ensured by automatic regulators, but control of the characteristics of each diesel generator is carried out by the duty or watch operator of the diesel power plant, as a rule, this is a specialist of 3-5 categories according to the qualification grid. In addition to control, his responsibilities include a number of other work issues.

The diesel driver has to monitor the fuel level in the supply tank and turn on the feed pump in a timely manner to replenish it. Special control is required over the temperature of the diesel engine, since its overheating, and this may be due to both lubricating oil pressure and problems with the cooling system, the task of the diesel driver on duty is to detect dangerous deviations in parameters in time and react to the best of his ability, right up to stopping the diesel engine and calling a repair team. Critical overheating of a diesel engine causes damage to the crankshaft journals and their scoring, and this is a major accident for a diesel engine and expensive repairs. The power supply of critical facilities and residential apartments depends on the experience and qualifications of the diesel engine operator; the work of the operator is not only responsible, but also well paid, and also in great demand.

A special position is occupied by drivers of mobile diesel power plants. A large number of mobile power plants serve temporary camps; natural resource development sites and agricultural field camps are limited in terms of diesel service. In such field shift conditions, a diesel power plant driver also becomes a mechanic and repairman, and an electrician too. All this is compensated by high wages, which allows a highly qualified diesel engine operator to earn decent money for skilled work.

The new wage system (NSWTS) abolished the previous tariff schedule, but this reform does not imply a reduction in wages. Until 2001, diesel engine operators worked in the range of categories from 5 to 8 categories, which amounted to a monthly tariff rate of 5,490 to 7,357 rubles per month. If a diesel power plant operator receives the position of engineer, then the salary is calculated for grades 6-11, and varies from 6092 to 9708 rubles per month. In fact, this rank grid is more often used to carry out estimate work, and each specific salary is discussed individually and specified in the employment contract.

Job Description of a Diesel Technician for a Diesel Power Plant[name of organization, enterprise, etc.]

This job description has been developed and approved in accordance with the provisions of other regulations governing labor relations in the Russian Federation.

1. General provisions

1.1. A diesel engine technician at a diesel power plant belongs to the category of workers and is directly subordinate to the head of the diesel power plant.

1.2. A person with special training is hired for the position of diesel diesel technician, without any work experience requirements.

1.3. A diesel engine technician at a diesel power station is hired and dismissed from work by order of the head of the diesel power plant.

1.4. A diesel engine technician should know:

Administrative and regulatory documents relating to the operation of power plants;

Technical characteristics, purpose and operating modes of power plants;

Rules and regulations on labor protection, industrial sanitation and fire safety;

Rules for the use of personal protective equipment;

Requirements for the quality of work (services) performed;

Production alarm;

Requirements for the rational organization of labor in the workplace.

2. Job responsibilities

2.1. The diesel diesel technician technician is assigned the following responsibilities:

Maintaining good condition, trouble-free and reliable operation of serviced devices and electrical equipment;

Checking the correct operating mode, heating of units, as well as the serviceability of fire extinguishing means;

Monitoring the readings of diesel power station devices every 2 hours;

Refueling a diesel power station from a fuel tanker;

Participation in the installation of equipment and commissioning of diesel power plants.

2.2. A diesel engine technician is prohibited from:

Put faulty units into operation;

Leave a running power plant unattended;

Allow unauthorized persons into the power plant premises.

3. Rights

3.1. A diesel diesel technician has the right to:

For all social guarantees provided for by law;

Require the management of the enterprise to provide assistance in the performance of their professional duties and the exercise of rights;

Require the creation of conditions for the performance of professional duties, including the provision of the necessary equipment, inventory, a workplace that complies with sanitary and hygienic rules and regulations, etc.;

For the free issuance of special clothing, special shoes and other personal protective equipment;

To pay additional expenses for medical, social and professional rehabilitation in cases of health damage due to an industrial accident and occupational disease;

Get acquainted with the draft decisions of the enterprise management concerning its activities;

Submit proposals for improvement of the organization and methods of work performed by the enterprise management for consideration;

Request personally or on behalf of your immediate supervisor documents, materials, tools, etc., necessary to perform your job duties;

Improve your professional qualifications;

Other rights provided for by labor legislation.

4. Responsibility

The diesel diesel technician is responsible for:

4.1. For failure to perform or improper performance of their job duties as provided for in this job description - within the limits determined by the current labor legislation of the Russian Federation.

4.2. For causing material damage to the employer - within the limits determined by the current labor and civil legislation of the Russian Federation.

4.3. For offenses committed in the course of carrying out their activities - within the limits determined by the current administrative, criminal, and civil legislation of the Russian Federation.

The job description has been developed in accordance with [name, number and date of document].

Head of HR department

[initials, surname]

[signature]

[day, month, year]

Agreed:

[initials, surname]

[signature]

[day, month, year]

I have read the instructions:

[initials, surname]

[signature]

[day, month, year]

Responsibility The diesel engine technician is responsible for: 4.1. For failure to perform or improper performance of one’s job duties as provided for in this job description - within the limits determined by the current labor legislation of the Russian Federation. 4.2. For causing material damage to the employer - within the limits determined by the current labor and civil legislation of the Russian Federation. 4.3. For offenses committed in the course of carrying out their activities - within the limits determined by the current administrative, criminal, and civil legislation of the Russian Federation. The job description has been developed in accordance with [name, number and date of document].

Job Description of a Diesel Technician for a Diesel Power Plant

Job responsibilities 2.1. The diesel engine technician of the diesel power plant is assigned the following responsibilities: - maintaining good condition, trouble-free and reliable operation of the serviced devices and electrical equipment; — checking the correct operating mode, heating of units, as well as the serviceability of fire extinguishing means; — monitoring the readings of diesel power plants every 2 hours; — refueling a diesel power station from a fuel tanker; — keeping diesel power station clean; — participation in the installation of equipment and commissioning of diesel power plants. 2.2. Diesel engine technicians are prohibited from: - putting faulty units into operation; — leave a running power plant unattended; — allow unauthorized persons into the premises of the power plant.


3. Rights 3.1.

Responsibilities of an electrician-diesel operator

Organization of their work, timely and qualified execution of orders, instructions and instructions from management, regulations on their activities. 3.3. Compliance with internal regulations, fire safety and traffic regulations of the Russian Federation.
3.4. Maintaining documentation required by current regulations. 3.5. Promptly taking measures, including timely informing management, to eliminate violations of safety regulations, fire safety and other rules that pose a threat to the activities of the institution, its employees and other persons.


3.6. For violation of labor discipline, legislative and regulatory acts, the diesel engine driver may be subject to disciplinary, material, administrative and criminal liability in accordance with current legislation, depending on the severity of the offense. 4.

Production instructions for the driver of diesel power plant (diesel power plant)

At the end of the working day, the diesel engine operator is obliged to: turn off the external power lines; stop the engine; carry out a control inspection of the power plant and clean the units from dust and dirt; check the tightness of the contacts on the current-carrying parts of the generator, clean the burnt contacts to a metallic shine; tidy up the workplace, collect oily rags and place them in a special metal box; tidy up and put tools and equipment in the designated place; inform the work manager or the person responsible for maintaining the machine in good condition about any problems that arise during operation. 3. RESPONSIBILITY The diesel engine operator is responsible for: 3.1.
Timely and high-quality implementation of assigned duties. 3.2.

Diesel generator maintenance personnel

Info

Persons at least 18 years of age who have passed a medical examination, theoretical and practical training, tested their knowledge of labor safety requirements in the prescribed manner and have received permission to work independently are allowed to work as a diesel engine operator. 1.7. The diesel engine operator is provided with special clothing and safety footwear in accordance with current standards.


1.8.

Attention

The diesel engine operator must know and strictly comply with the requirements for labor protection, fire safety, and industrial sanitation. 1.9. The diesel engine operator must: use the machine for its intended purpose during operation, in accordance with the manufacturer’s instructions; maintain the car in technically sound condition.

Electromechanic of diesel-electric stations

I APPROVED" Name of the employer's position (signature) (last name, initials) Date of approval Production instructions for the driver of a diesel power plant (diesel power plant) (name of profession, position or type of work) (designation) year 20 These production instructions for the driver of a diesel power plant (diesel power plant) have been developed on the basis of the Unified Tariff and Qualification Directory (ETKS N 3), Rules for the Technical Operation of Diesel Power Plants (PTED), approved by the Ministry of Fuel and Energy of the Russian Federation on 02/09/93. 1. GENERAL REQUIREMENTS 1.1. The driver of a diesel power plant (diesel power plant), then according to the test, the driver of a diesel power plant, is a worker and reports directly to the foreman (the head of the structural unit).

1.2. The diesel engine operator must perform his duties in accordance with the requirements of these Instructions. 1.3.

Vacancies and work: “diesel electrician” in Moscow

The diesel engine operator is prohibited from: pouring gasoline into the inlet pipe when starting the engine; grip the handle with your fingers to avoid the handle striking back when starting an overheated engine; use oxygen instead of compressed air or nitrogen when starting the engine; use an open flame when filling the fuel tank, as well as when inspecting the fuel system and warming up the fuel and oil lines; hit the caps of power plant fuel tanks and fuel barrels with steel (or other objects capable of causing sparks) when opening them; measure the oil level with random objects; exceed the rated generator loads specified in the machine's passport. 2.5. In case of emergency situations, the driver of the diesel power plant is obliged: in the event of fuel ignition at the power plant, the driver is obliged to stop allowing fuel to the sources of fire.

Job Description for Diesel Electrician

I approve [position, signature, full name of the manager or other official authorized to approve the job description] [date, month, year] M.P. Job description of a diesel engine technician at a diesel power plant [name of organization, enterprise, etc.]

This job description has been developed and approved in accordance with the provisions of the Labor Code of the Russian Federation and other regulations governing labor relations in the Russian Federation. 1. General provisions 1.1. A diesel engine technician at a diesel power plant belongs to the category of workers and is directly subordinate to the head of the diesel power plant.

A person with special training is hired for the position of diesel diesel technician, without any work experience requirements. 1.3. A diesel engine technician at a diesel power station is hired and dismissed from work by order of the head of the diesel power station.

One of the most important provisions of an electrician’s job description is a clear requirement for the qualifications of candidates, namely the point regarding the employee’s safety group. In our sample job description for an electrician, we consider the fourth safety group, but depending on the tasks it can be the third or fifth. The main thing in the job responsibilities of an electrician is to ensure trouble-free and reliable operation of the serviced devices and electrical equipment. Download v.doc To the list of job descriptions Job description of an electrician APPROVEDGeneral DirectorLast name I.O. " " d. 1. General provisions 1.1. An electrician belongs to the category of workers.1.2. An electrician is appointed to a position and dismissed from it by order of the General Director on the recommendation of the Chief Engineer.1.3. The electrician reports directly to the chief engineer.1.4.

Job Description of a Diesel Technician for a Diesel Power Plant

To do this, an electromechanical diesel operator must closely monitor the operation of the station unit, stand guard near it, and take measures to eliminate malfunctions. When winding down the station, the diesel electrician disconnects the load, stops the engine and prepares the ESD-10-VS power station for transportation. RESPONSIBILITIES OF ELECTRICIANS Electricians are required to know the structure of the station, especially the structure of lighting and cable networks and the rules for their maintenance; keep the station's property in exemplary cleanliness and constant readiness for work; by personal demonstration, train assigned sappers in work techniques for deploying and dismantling station property.
When setting up a station, electricians unload property, install lighting and lay a cable network.

Responsibilities of an electrician-diesel operator

Attention

An electromechanic of diesel-electric stations (DES), power and lighting units of the technical and launch complexes works on the control panel of the diesel power plant, ensuring its maintenance in a “hot reserve” state during experimental testing work at the technical and launch complexes. He must know the design, rules of operation and maintenance of diesel power plants, and comply with safety requirements during operation. The professional activity of a specialist is performing.


Info

He is subordinate to the squad commander and works under his leadership as part of the combat crew. Business contacts with settlement numbers are frequent, carried out during direct communication or with the help of technical (intercom) devices. The work is generally varied and is carried out at a forced pace and with a variable rhythm.

Production instructions for the driver of diesel power plant (diesel power plant)

Therefore, there must be a driver at the power plant who will ensure its operation. He must have at least a secondary specialized education and an electrical safety certificate. The responsibilities of the driver include: Daily maintenance of the diesel power plant - checking the condition before each start (fastening, grounding, absence of leaks of technical fluids and contaminants), refueling, connecting consumers, turning on equipment, monitoring its operation to avoid emergency situations. Periodic preventive maintenance, which is carried out either according to a calendar period (once every two weeks, month), or upon the production of a certain number of engine hours (50, 150, 450). Includes duties and cleaning of filters and other systems, changing oil and consumables. Troubleshooting diesel power plants.

Diesel generator maintenance personnel

Responsibility The diesel engine technician is responsible for: 4.1. For failure to perform or improper performance of one’s job duties as provided for in this job description - within the limits determined by the current labor legislation of the Russian Federation. 4.2. For causing material damage to the employer - within the limits determined by the current labor and civil legislation of the Russian Federation.
4.3. For offenses committed in the course of carrying out their activities - within the limits determined by the current administrative, criminal, and civil legislation of the Russian Federation. The job description has been developed in accordance with [name, number and date of document].

Electromechanic of diesel-electric stations

RIGHTS The diesel engine operator has the right: 4.1. Receive from enterprise employees the information necessary to carry out their activities. 4.2. Use information materials and regulatory documents necessary to perform your job duties. 4.3. Pass certification in the prescribed manner with the right to receive the appropriate qualification category.
4.4. Request and receive the necessary materials and documents related to issues of his activities and the activities of his subordinate employees. 4.5. Interact with other services of the enterprise on production and other issues included in its functional responsibilities. 4.6. Enjoy all labor rights in accordance with the Labor Code of the Russian Federation.
5. FINAL PROVISIONS 5.1.

Vacancies and work: “diesel electrician” in Moscow

Installs new electrical networks.2.3. Conducts scheduled preventive maintenance (PPR) of the electrical part of the equipment in accordance with the PPR schedule.2.4. Identifies the causes of wear, takes measures to prevent and eliminate them.2.5. Ensures proper operation, timely high-quality repairs in accordance with maintenance instructions, current technical conditions and standards, and maintenance of the transformer TP-2 and the electrical networks of the enterprise.2.6.

Eliminates malfunctions in the operation of devices, their repair, installation and adjustment. 3. Rights of an electrician An electrician has the right: 3.1. Receive information and instructions from the chief engineer regarding the emergence of new types of work on the site. 3.2. Require the administration to ensure labor protection, safety and fire safety rules.3.3.

Require the provision of special clothing in accordance with current standards. 3.4.

Job Description for Diesel Electrician

A person with secondary education and appropriate training in the specialty (secondary vocational education) is appointed to the position of diesel engine operator. 1.4. The diesel engine operator must know: technical conditions for testing products; design of machines (mechanisms), rules and instructions for their operation, maintenance and preventive repairs; methods of performing work using appropriate machines; technical requirements for the quality of work performed, materials and elements of structures; consumption standards for fuels, lubricants and electricity. 1.5. The diesel engine operator is appointed to the position and dismissed from the position by order of the head of the institution in accordance with the current legislation of the Russian Federation. 1.6.


If a diesel power plant is serviced by two teams - electricians and diesel operators, then both teams, having thoroughly studied the components and systems entrusted to them directly, should have an understanding of the operation of all diesel power station equipment as a whole. Persons servicing diesel power plants must be tested by a special commission on their knowledge of the rules for the technical operation of electrical installations, safety and fire safety regulations, operating instructions, technical minimums for the equipment being serviced, and methods of providing first aid in case of accidents. To gain practical skills in maintenance and more detailed on-site familiarization, each employee servicing diesel power plants must undergo an on-the-job internship lasting at least two weeks under the guidance of a more experienced employee. After this, he is allowed to work independently.

Job Description for Diesel Generator Set Operator

Attention

To pay additional costs for medical, social and professional rehabilitation in cases of health damage due to an industrial accident and occupational disease. 3.4. Get acquainted with draft decisions of the enterprise management concerning its activities. 3.5. Submit proposals for improvement of the organization and methods of work performed by the enterprise management for consideration.


3.6.

Operation of a diesel generator set

  • Periodically observe the operation of the exciter brush apparatus and rotor slip rings;
  • Evenly distribute the load (in the absence of automation) between parallel operating generators;
  • Periodically listen to the generator for knocking and extraneous noise;
  • If the readings of one of the stator or rotor instruments suddenly disappear, check with other instruments to see if this is the result of damage to the instrument itself, supply circuits, etc.
  • If the device or supply network is damaged, then, without changing the operating mode of the generator, it is necessary to take measures to eliminate the malfunction.

Safety instructions for operation and maintenance of a diesel power plant The diesel power plant of the diesel power plant does not create any danger when operated correctly.

Diesel generator maintenance personnel

The same applies to the oil level - if there is a shortage, it should be topped up. Moreover, it is recommended to use only original brands of consumables and high-quality fuel, since an attempt to save money in this case can lead to equipment breakdown or shorten its service life. You should also check the integrity of the connections in all systems (cooling, fuel and lubrication), the tightness of the air purifier connections and the tightness of the air damper mechanism.
Many experts do not advise starting a diesel generator from a cold state - the optimal oil temperature at start-up is considered to be 30-35 degrees; the use of a heater, which can be included in the kit or installed separately, will help to heat the oil to the required temperature.

Power plants in St. Petersburg. energy house

When preparing the diesel engine for operation, you should check the degree of discharge of the batteries and the serviceability of the ignition system. Starting a diesel engine with a starter when the battery is discharged more than 50% is not allowed. The supply fuel tank must be filled with fuel and the fuel tank valve must be set to the “Open” position.
The fuel level in the supply tank is controlled by the fuel level indicator. A fully filled supply tank ensures continuous operation of the electric unit for at least 4 hours. It is necessary to ensure that there is no air in the fuel system, fill the supply and additional oil tanks, and also fill the internal circuit of the cooling system with water (if any) and check the water circulation in the external cooling system circuit. There should be no leaks in the fuel supply, lubrication and cooling systems of the diesel engine.

Rules for the operation of diesel generator sets (DGS)

Use only a special lifting device on the diesel engine body or on the support frame.

  • Make sure that the lifting equipment is in good working order and has the required capacity.
  • When lifting the diesel engine, there should be no people on it, under it or between it and the crane.

Fire and explosion safety during operation and maintenance of a diesel power plant:

  • Make sure that there are fire extinguishers of BC and ABC classes near the diesel power station.
  • Make sure that the room where the diesel generator is located is well ventilated.
  • Keep the room, floor and diesel power station clean. Clean up spilled fuel, oil, electrolyte or coolant immediately. Store oily rags in closed metal boxes.
  • Do not smoke, do not allow open flames near fuel or batteries.

Info

Request a call back Home » Useful information » Operating rules » Operating rules for diesel generator sets (DGS) A diesel generator is a source of autonomous or emergency power supply - it is used in enterprises for backup power supply of equipment that should not be idle in case of interruptions in the central power supply, or how the main source of electricity in places where for some reason there is no other source of energy. Such units are complex technical devices, so whatever role they play, one of the important issues is the proper storage, maintenance and operation of the diesel generator. Compliance with certain rules will help you make the most of the purchased equipment and significantly extend its service life.

Responsibilities of a diesel operator servicing diesel generator sets

To pay additional costs for medical, social and professional rehabilitation in cases of health damage due to an industrial accident and occupational disease. 3.4. Get acquainted with draft decisions of the enterprise management concerning its activities. 3.5. Submit proposals for improvement of the organization and methods of work performed by the enterprise management for consideration.
3.6.

Request personally or on behalf of your immediate supervisor documents, materials, tools, etc., necessary to perform your job duties. 3.7. Improve your professional qualifications. 3.8. Other rights provided for by labor legislation. 4. Responsibility The diesel generator operator is responsible for: 4.1.

Just following this rule will help to avoid most problems in the operation of power equipment. Before starting Before starting the generator, you must make sure that there are no malfunctions; if any are identified, you should take measures to eliminate them. To do this, first carry out a visual inspection of the unit to identify visible damage, check the state of charge of the batteries and the condition of the ignition system.
After this, the insulation resistance of the device is measured - if it is less than 0.5 mOhm, you need to clean the insulation parts from dirt, dry and wipe them. Before starting the generator, the fuel tank valve must be opened; it would be useful to check the presence of fuel in the tank and make sure that there is no air in the fuel system. The cooling system must be charged - depending on the brand of the generator, water, antifreeze or antifreeze can be used for this.

Safety rules for installing and assembling a diesel power plant:

  • Read the sections on installation and operation of diesel power plants.
  • Carry out electrical installation work in accordance with the rules and standards for electrical safety, including compliance with the requirements for grounding and protection against short circuits to ground.
  • For stationary diesel power plants with a remote fuel supply system, make sure that the latter is in accordance with the rules and standards.
  • Make sure that the exhaust system and DES mufflers are free of flammable materials, have protective thermal insulation and will not pose a danger to personnel.
  • Do not lift the diesel engine using the lifting eyes of the generator or engine.