Line electrician for installation of high voltage overhead lines and contact network. Training of an electrician-lineman on the installation of high-voltage overhead lines and a contact network Work as an electrician as a lineman shift from direct employers

Job electrician lineman vacancy electrician lineman in Moscow. Vacancy electrician lineman from a direct employer in Moscow job advertisements electrician lineman Moscow, vacancies of recruitment agencies in Moscow, looking for a job electrician lineman through recruitment agencies and from direct employers, vacancies electrician lineman with and without work experience. The site of announcements about part-time work and work Avito Moscow job vacancies electrician lineman from direct employers.

Work in Moscow electrician lineman

Site work Avito Moscow work fresh vacancies electrician lineman. On our site you can find a highly paid job as an electrician lineman. Look for a job as an electrician lineman in Moscow, view vacancies on our job site - a job aggregator in Moscow.

Avito jobs Moscow

Work electrician lineman on the site in Moscow, vacancies electrician lineman from direct employers Moscow. Vacancies in Moscow without work experience and highly paid with work experience. Vacancies electrician lineman for women.

We always have a large number of fresh current vacancies on our website. Use filters to quickly search by parameters.

For successful employment, it is desirable to have a specialized education, as well as possess the necessary qualities and work skills. First of all, you need to carefully study the requirements of employers in the chosen specialty, then start writing a resume.

You should not send your resume to all companies at the same time. Choose suitable vacancies, focusing on your qualifications and work experience. We list the most significant skills for employers that you need to successfully work as an electrician as a lineman in Russia:

Top 7 Key Skills You Need to Get a Job

Also quite often in vacancies there are the following requirements: electric power industry, construction and negotiation.

When preparing for an interview, use this information as a checklist. This will help you not only to please the recruiter, but also to get the desired job!

Analysis of vacancies in Russia

According to the results of the analysis of vacancies published on our website, the indicated starting salary, on average, is - 71,634. Keep in mind that these figures are statistics. The actual salary during employment can vary greatly depending on many factors:
  • Your previous work experience, education
  • Type of employment, work schedule
  • Company size, industry, brand, etc.

Salary depending on the experience of the applicant

This job description has been translated automatically. Please note that automatic translation does not provide 100% accuracy, so there may be minor translation errors in the text.

Instructions for the position " Line electrician for installation of high voltage overhead lines and contact network of the 3rd category", presented on the website, complies with the requirements of the document - "DIRECTORY of qualification characteristics of workers' professions. Issue 64. Construction, installation and repair and construction work. (Including additions approved by: order of the State Committee for Construction and Architecture N 25 of 08.08.2002, N 218 of 12.22.2003, N 149 of 08.29.2003, letter of the State Committee for Construction and Architecture N 8 / 7-1216 of December 15, 2004, by order of the Ministry of Construction, Architecture and Housing and Communal Services N 9 of December 2, 2005, N 163 of May 10, 2006 N 399 of December 5, 2006, by order of the Ministry of Regional Development , construction and housing and communal services of Ukraine N 558, 12/28/2010)", which was approved by order of the State Committee for Construction, Architecture and Housing Policy of Ukraine on 10/13/1999 N 249. Agreed by the Ministry of Labor and Social Policy of Ukraine. Entered into force from 1 January 2000
The status of the document is "valid".

Preface to job description

0.1. The document comes into force from the moment of its approval.

0.2. Document developer: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _.

0.3. Document approved: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _.

0.4. Periodic verification of this document is carried out at intervals not exceeding 3 years.

1. General Provisions

1.1. The position "Electrician-linear for the installation of overhead lines of high voltage and contact network of the 3rd category" belongs to the category "Workers".

1.2. Qualification requirements - complete or basic general secondary education. Vocational education without requirements for work experience or obtaining a profession directly at the factory, advanced training and work experience as an electrician-linearist in the installation of high-voltage overhead lines and a contact network of the 2nd category for at least 1 year.

1.3. Knows and applies:
- types of fasteners, fittings, insulators, wires and cables;
- the structure of a simple electric and pneumatic hand tool;
- types of supports for overhead power lines, designed for voltages up to 20 kV;
- the main types of foundations for supports and electrical structures of open substations and methods for their installation;
- device and rules for using simple rigging means;
- grounding and grounding rules.

1.4. The line electrician for the installation of high voltage overhead lines and the contact network of the 3rd category is appointed to the position and dismissed by order of the organization (enterprise / institution).

1.5. The line electrician for the installation of high voltage overhead lines and the contact network of the 3rd category reports directly to _ _ _ _ _ _ _ _ _ _ .

1.6. The line electrician for the installation of high-voltage overhead lines and the 3rd category contact network directs the work of _ _ _ _ _ _ _ _ _ _ .

1.7. The line electrician for the installation of high-voltage overhead lines and the contact network of the 3rd category during his absence is replaced by a person appointed in the prescribed manner, who acquires the appropriate rights and is responsible for the proper performance of the duties assigned to him.

2. Description of work, tasks and job responsibilities

2.1. Performs simple work on the construction of overhead power lines, contact networks and open switchgears.

2.2. Knows, understands and applies the current regulatory documents relating to its activities.

2.3. Knows and fulfills the requirements of regulatory acts on labor and environmental protection, complies with the norms, methods and techniques for the safe performance of work.

3. Rights

3.1. The line electrician for the installation of high voltage overhead lines and the 3rd category contact network has the right to take actions to prevent and eliminate any violations or inconsistencies.

3.2. An electrician-lineman for the installation of high-voltage overhead lines and a contact network of the 3rd category has the right to receive all social guarantees provided for by law.

3.3. The line electrician for the installation of high-voltage overhead lines and the contact network of the 3rd category has the right to demand assistance in the performance of his duties and the exercise of rights.

3.4. An electrician-lineman for the installation of high-voltage overhead lines and a contact network of the 3rd category has the right to demand the creation of organizational and technical conditions necessary for the performance of official duties and the provision of the necessary equipment and inventory.

3.5. An electrician-lineman for the installation of high-voltage overhead lines and a contact network of the 3rd category has the right to get acquainted with draft documents relating to his activities.

3.6. The line electrician for the installation of high-voltage overhead lines and the contact network of the 3rd category has the right to request and receive documents, materials and information necessary to fulfill his job duties and instructions from the management.

3.7. An electrician-lineman for the installation of high-voltage overhead lines and a contact network of the 3rd category has the right to improve his professional qualifications.

3.8. The line electrician for the installation of high-voltage overhead lines and the 3rd category contact network has the right to report all violations and inconsistencies identified in the course of his activities and make proposals for their elimination.

3.9. An electrician-lineman for the installation of high-voltage overhead lines and a contact network of the 3rd category has the right to familiarize himself with documents defining the rights and obligations of his position, criteria for assessing the quality of performance of official duties.

4. Responsibility

4.1. The line electrician for the installation of high-voltage overhead lines and the 3rd category contact network is responsible for failure to fulfill or untimely fulfillment of the duties assigned by this job description and (or) non-use of the rights granted.

4.2. The line electrician for the installation of high-voltage overhead lines and the 3rd category contact network is responsible for non-compliance with the rules of internal labor regulations, labor protection, safety, industrial sanitation and fire protection.

4.3. The line electrician for the installation of high-voltage overhead lines and the 3rd category contact network is responsible for disclosing information about the organization (enterprise / institution) that is a trade secret.

4.4. The line electrician for the installation of high-voltage overhead lines and the 3rd category contact network is responsible for non-fulfillment or improper fulfillment of the requirements of the internal regulatory documents of the organization (enterprise / institution) and the legal orders of the management.

4.5. An electrician-lineman for the installation of high voltage overhead lines and a contact network of the 3rd category is responsible for offenses committed in the course of his activities, within the limits established by the current administrative, criminal and civil legislation.

4.6. The line electrician for the installation of high voltage overhead lines and the contact network of the 3rd category is responsible for causing material damage to the organization (enterprise / institution) within the limits established by the current administrative, criminal and civil legislation.

4.7. The line electrician for the installation of high-voltage overhead lines and the contact network of the 3rd category is responsible for the misuse of the granted official powers, as well as their use for personal purposes.

5. Examples of work

5.1. Reinforcing and equipping uninstalled supports and structures with pins, hooks and insulators.

5.2. Compilation of insulators and linear fittings into insulating hangers for overhead power lines, designed for voltages up to 20 kV.

5.3. Rolling out of steel ropes, cables and single-core wires with the installation of drums.

5.4. Lifting of wires on single-stand towers of overhead power lines, designed for voltage up to 20 kV.

5.5. Installation of grounding and grounding of overhead power lines or contact networks.

5.6. Deepening of ground electrodes with mechanized tools.

5.7. Cutting and cutting of wires and cables.

5.8. Waterproofing of reinforced concrete structures.

5.9. Painting of uninstalled supports and structures of outdoor substations.

5.10. Winding on drums of wires and cables.

5.11. Sewing drums with wound wires and cables.

5.12. Support numbering.

5.13. Fastening on supports of tables and posters.

5.14. Dismantling of wires and cables of overhead power lines or contact networks rated for voltage up to 1 kV.

Unified Tariff and Qualification Directory of Works and Professions of Workers (ETKS), 2019
Issue No. 3 ETKS
The issue was approved by the Order of the Ministry of Health and Social Development of the Russian Federation dated April 6, 2007 N 243
(as amended by: Orders of the Ministry of Health and Social Development of the Russian Federation of November 28, 2008 N 679, of April 30, 2009 N 233)

Line electrician for installation of high voltage overhead lines and contact network

§ 448

Job Description. Production of small fastening parts that do not require exact dimensions. Deepening of ground electrodes manually. Cleaning of uninstalled steel supports of overhead lines (VL) and structures of open substations. Painting parts for attaching attachments and grounding bars. Brushing the details of wooden supports with antiseptic compounds. Removing the casing from the drums and disassembling them. Rolling wires and cables manually.

Must know: main brands of linear fittings, insulators, wires and cables; range of steel and hardware; rules for handling antiseptic compounds and methods for antiseptic timber; railway signaling rules; methods of coloring wires and grounding buses; ways of deepening ground electrodes manually; name and purpose of hand tools and devices used.

§ 449

Job Description. Installing or removing pin hooks and insulators from uninstalled poles. Rolling out steel ropes, cables and single-core wires with the installation of drums. Lifting wires to the supports of overhead lines with voltage up to 20 kV using rods and poles. Cutting and cutting of wires and cables. Laying of grounding slopes, installation of the ground loop. Deepening of earth electrodes with a mechanized tool. Waterproofing of reinforced concrete structures. Painting of uninstalled steel supports of overhead lines and structures of open substations. Numbering of supports and fastening of tables and posters. Winding wires and cables on drums with sewing of drums. Delivery of structures and materials. Moving structures manually.

Must know: types of fasteners, fittings, insulators, wires and cables; device used electrified and pneumatic hand tools; the main types of building structures of overhead lines and open substations; device and rules for using the rigging equipment used; grounding and grounding rules.

§ 450

Job Description. Assembly of supports for overhead lines and structures of open substations weighing up to 5 tons. Procurement of parts for wooden supports. Installation and dismantling of overhead line supports and structures of open substations weighing up to 1.5 tons. Rolling out and lifting wires onto overhead line supports with a voltage of up to 150 kV and cables - up to 750 kV. Production of descents, jumpers, loops and half loops from wires and cables. Installation of arresters. Transitional protection device. Assembly of insulators and fittings into insulating hangers for overhead lines with voltage up to 220 kV. Connection of wires and cables with a cross section of up to 70 mm2. Fixing wires on pin insulators of overhead lines with voltage up to 1 kV. Marking and installation of link and elastic strings on the carrier cable from the ground. Installation of fittings on consoles and flexible crossbars. Installation of load limiters of compensated anchoring, fixing and feeder brackets on supports. Installation of the middle anchor on the ground. Suspension of a carrier cable from the ground on a support. Inserting insulators into wires and cables on the ground. Installation of interrail connections. Manufacture and connection of cable braces to supports. Completion of rigid crossbars. Painting of the installed supports of overhead lines and structures of open substations. Dismantling of wires and cables of overhead lines and contact networks with voltage up to 150 kV. Straightening of single-column supports with voltage up to 20 kV. Arrangement of cable channels and emergency oil drain. Installation of inputs of overhead lines in buildings. Installation of luminaires on poles.

Must know: methods for assembling poles of overhead lines and structures of open substations weighing up to 5 tons; methods of installation of overhead line supports and structures of open substations weighing up to 1.5 tons; the order of layout and assembly of insulators and fittings into insulating hangers for overhead lines with voltage up to 220 kV; methods of connecting wires and cables with a cross section of up to 70 mm2; methods of lifting and fastening wires and cables on supports; the purpose and methods of manufacturing and installing tires, descents, jumpers and loops from wires and cables; ways to install load limiters and feeder brackets on supports; ways to install arresters; types and methods of installation of protections for transitions; rules for the use of mechanized rigging equipment and tools; types of fixtures and how to install them.

§ 451

Job Description. Assembly of supports for overhead lines and structures of open substations weighing over 5 to 10 tons. Installation and dismantling of supports for overhead lines and structures of open substations weighing over 1.5 to 5 tons, except for supports on guy wires hinged on foundations. Connection of wires and cables with a cross section of more than 70 to 800 mm2. Rolling out stranded wires from non-ferrous metals. Rolling and lifting of wires on the supports of overhead lines with a voltage of over 150 to 750 kV and cables - over 750 kV. Fastening wires on pin insulators of overhead lines with a voltage of over 1 kV. Assembly of insulators and fittings into insulating hangers for overhead lines with a voltage of over 220 kV. Installation of vibration dampers and spacers on wires and cables. Tensioning and regulation of wires and cables on overhead lines with voltage up to 150 kV. Relocation of wires and cables on supports of overhead lines with voltage up to 150 kV. Installation of loops. Installation of a contact wire limiter. Installation of single and double track consoles. Installation of flexible crossbars. Installation of medium anchors. Installation of electrical connectors and outlets of all types. Rigid anchoring of the carrying cable, power and reinforcing wires. Lifting the chain suspension under the heel of the console and transferring to the saddle. Dismantling of wires and cables of overhead lines with voltage over 150 kV. Editing complex supports of overhead lines with voltage up to 20 kV.

Must know: methods for laying out pits and places for piling at the pickets of overhead lines and contact networks; methods for assembling poles of overhead lines and structures of open substations weighing more than 5 to 10 tons; methods for installing overhead line supports and structures of open substations weighing over 1.5 to 5 tons; the procedure for laying out and assembling insulators and fittings into insulating hangers for overhead lines with a voltage of over 220 kV; the procedure for phasing wires of contact networks and methods for checking the work performed according to the schemes; methods of connecting wires and cables with a cross section of more than 70 to 800 mm2; methods of rolling multiwire wires from non-ferrous metals; the procedure for rolling and lifting cables to the supports of overhead lines with a voltage of over 750 kV and wires - over 150 to 750 kV; methods for installing spacers, vibration dampers, on wires and cables of overhead lines and contact wire limiters; methods of mounting loops, flexible crossbars, mates, anchor sections; rules for regulating wires and cables on overhead lines with a voltage of up to 150 kV and contact suspension circuits on hauls and stations; methods of rigid anchoring of wires on the supports of the contact network; methods of laying wires and cables on supports of overhead lines with voltage up to 150 kV; ways of installation and dismantling of arrows and intersections of the contact network.

§ 452

Job Description. Assembly of overhead line supports and structures of open substations weighing over 10 to 25 tons. Installation and alignment of reinforced concrete foundations. Installation and dismantling of overhead line supports and structures of open substations weighing more than 5 to 20 tons and supports on guys, hingedly installed on foundations, weighing up to 15 tons. Connection of wires with a cross section of more than 800 mm2. Rolling and lifting of wires on the supports of overhead lines with a voltage of over 750 kV. Installation of a load compensation unit for the tension of contact wires. Compensated anchoring of contact wire and carrying cable. Installation of fixing braces of a chain suspension, mates of anchor sections, air arrows, contact network in artificial structures, sectional insulators. Installation of supports on the main railways in operation. Tensioning and regulation of wires and cables on overhead lines with voltages over 150 to 750 kV. Relocation of wires and cables on the supports of overhead lines with a voltage of over 150 to 750 kV. Installation of wire transpositions on overhead lines with voltage up to 750 kV. Editing of supports of overhead lines with voltage over 20 kV. Breakdown of the route of overhead lines with voltage up to 20 kV.

Must know: methods for assembling poles of overhead lines and structures of open substations weighing over 10 to 25 tons; methods of installing overhead line supports and structures of open substations weighing over 5 to 20 tons; rules for installing transpositions of wires on overhead lines with voltage up to 750 kV; methods of connecting wires with a cross section of more than 800 mm2; rules for installing wires and cables at crossings; methods of compensated anchoring of contact wire and carrier cable; installation methods for chain suspension braces, anchor sections, air arrows, contact network in artificial structures, sectional insulators; methods of installation and alignment of supports on the main and station lines of railways; types of portable radio stations and rules for handling them; types of theodolites and levels and rules for using them.

§ 453

Job Description. Assembly of overhead line supports and open substation structures weighing over 25 tons. Installation and dismantling of overhead line supports and open substation structures weighing over 20 tons and supports on guy wires hinged on foundations weighing over 15 tons. Installation of monolithic foundations. Installation of transpositions of wires of overhead lines with voltage over 750 kV. Installation of wires and cables at crossings over large water barriers. Tensioning, regulation and relaying of wires and cables on overhead lines with a voltage of over 750 kV. Installation of foundations, supports, wires and cables using helicopters. Restoration of the breakdown of individual sections of the route, elevations of foundations and axes of pits of overhead lines with a voltage of over 20 kV.

Must know: methods for assembling poles of overhead lines and structures of open substations weighing more than 25 tons; methods of installation of overhead line supports and structures of open substations weighing more than 20 tons and supports on guys, installed hingedly on foundations, weighing more than 15 tons; rules for the arrangement and alignment of monolithic reinforced concrete foundations; rules for the installation of wires and cables at crossings through large water barriers; methods for performing installation work during the construction of overhead lines using helicopter technology; rules for regulating wires and cables on overhead lines with a voltage of over 750 kV; ways to restore the breakdown of individual sections of the overhead line (industrial picketage).

Requires secondary vocational education.

The training of an electrician-lineman in the installation of high-voltage overhead lines and a contact network is carried out in accordance with the Order of the Ministry of Education and Science of the Russian Federation No. 739 dated August 2, 2013 "On approval of the federal state educational standard of secondary vocational education of secondary vocational education by profession 140443.01 Electrician-linear for the installation of high-voltage overhead lines and a contact network", "List of occupations of workers, positions of employees for which vocational training is carried out", approved by order of the Ministry of Education and Science No. 513 of 02.07.2013 vocational training”, the requirements of the Unified Tariff and Qualification Directory of Works and Professions of Workers, the All-Russian Classifier of Workers' Professions, Positions of Employees and Wage Categories.

High voltage overhead lines are power lines with a voltage of over 1000 V, designed for the transmission and distribution of electrical energy through wires located in the open air and attached to supports (poles, masts, etc.) using insulators and fittings. High voltage overhead lines are used to transmit energy of high power and over long distances.

Overhead lines and contact network consist of sections mechanically separated from each other. If the wires of one section are broken, the other does not fail. This separation simplifies installation, allowing it to be performed in separate sections.

The profession of an electrician-lineman for the installation of high voltage overhead lines and a contact network requires the following knowledge: types of fasteners, fittings, insulators, wires and cables; device used electrified and pneumatic hand tools; the main types of building structures of overhead lines and open substations; device and rules for using the rigging equipment used; grounding and grounding rules; methods for laying out pits and places for piling at the pickets of overhead lines and contact networks; methods for assembling poles of overhead lines and structures of open substations; installation methods for overhead lines and structures of open substations; the order of layout and assembly of insulators and fittings into insulating suspensions for overhead lines; the procedure for phasing wires of contact networks and methods for checking the work performed according to the schemes; ways of connecting wires and cables with different sections; methods of rolling multiwire wires from non-ferrous metals; the procedure for rolling and lifting cables to the supports of overhead lines and wires; methods for installing spacers, vibration dampers, on wires and cables of overhead lines and contact wire limiters; methods of mounting loops, flexible crossbars, mates, anchor sections; rules for regulating wires and cables on overhead lines and contact suspension circuits on hauls and stations; methods of rigid anchoring of wires on the supports of the contact network; ways of laying wires and cables on the supports of overhead lines with voltage; methods of mounting and dismantling arrows and intersections of the contact network, etc.

To work as an electrician-lineman for the installation of high-voltage overhead lines and a contact network, a specialist must undergo professional training, no more than once a year and at least once every 5 years, take short-term refresher courses in the amount of at least 72 hours in order to acquire new knowledge and skills and increase in rank, have a medical book with no contraindications, admission to the electrical safety group is not lower than group 3 up to 1,000 V. It is important that for work as an electrician-lineman for the installation of high voltage overhead lines and a contact network, persons under 18 years of age not allowed.

Tuition fees and terms of development

ANO DPO "Comprehensive Training Center for Retraining Personnel" conducts vocational training in the following programs:

Form of study: full-time, part-time, remote with the use of "Internet" technologies.

In the process of mastering the training program, developed in accordance with the Order of the Ministry of Education and Science of the Russian Federation No. 739 dated August 2, 2013 "On approval of the federal state educational standard of secondary vocational education of secondary vocational education by profession 140443.01 Line electrician for the installation of high voltage overhead lines and contact networks", " The list of professions of workers, positions of employees for which vocational training is carried out ”, approved by order of the Ministry of Education and Science No. 513 dated July 2, 2013 “On approval of the List of professions of workers, positions of employees for which vocational training is carried out" for mastering the working profession of an electrician-liner for installation overhead high voltage lines and contact network, the following issues are being studied:

  • Fundamentals of Electrical Engineering
  • Electrical materials science
  • Reading blueprints
  • Occupational Safety and Health. Providing first aid at work
  • Electrical safety. Industrial safety rules
  • Installation of high voltage overhead power lines (VL)
  • High voltage overhead power lines with insulated wires (VLI)
  • Overhead power lines of high voltage, performed by wires with a protective insulating sheath (VLZ)
  • Installation and repair of VL, VLI, VLZ.
  • Mechanization of repair work on overhead lines.
  • Rigging work
  • Tests and measurements of VL, VLI, VLZ.

Upon completion of training issued

  • A certificate for each employee who has passed certification;
  • Minutes of the attestation commission with a list of employees who have passed attestation.

How to be trained as an electrician-linear for the installation of high voltage overhead lines and a contact network

After completing vocational training (either in a specialized school or training center), an electrician-lineman for the installation of high voltage overhead lines and a contact network needs to take annual short-term refresher courses in the amount of at least 72 hours, no more than 1 time per year and no less than 1 once every 5 years.

Benefits of working with ANO DPO "Integrated Training Center for Retraining Personnel"

  • all training programs are developed by teachers, taking into account modern educational and methodological materials using new technologies in teaching;
  • a convenient form of an electronic library for the educational material of the course has been developed for you;
  • the cost of training for an electrician-lineman for the installation of high-voltage overhead lines and a contact network is significantly lower than that of other training centers;
  • training takes place at a convenient time for you and in the form that is required for your organization.

What does not undergo advanced training for more than 5 years entail?

In accordance with Part 1 of Article 9.1 of the Code of Administrative Offenses of the Russian Federation 1. Violation of industrial safety requirements or conditions for the implementation of activities in the field of industrial safety of hazardous production facilities entails the imposition of an administrative fine:

  • for citizens - in the amount of 2,000 to 3,000 rubles;
  • for officials - from 20,000 to 30,000 or disqualification for a period of 6 months to 1 year;
  • for legal entities - from 200,000 to 300,000 or administrative suspension of activities for up to 90 days.

Required documents