Boiler aogv 50 technical specifications. Special boiler steel - a guarantee of high boiler performance ross

Product description Floor standing gas boiler ROSS AOGV-50 D Lux

AOGV-boilers ROSS Lux are designed for heating rooms equipped with a chimney. A wide range of models of this series allows you to choose an AOGV-boiler that best meets the requirements of the buyer, which in turn ensures the most efficient and economical operation of the heating system. Double-circuit models provide heating of water for domestic needs. All models are available with both vertical and horizontal chimney outlets.

AOGV-boilers "Lux" are successfully used in the construction of modern hermetic heating systems, both classic radiator and underfloor heating systems.

Advantages of AOGV-boilers ROSS of the Lux class:

Profitable - high efficiency - 92%.

We achieved high efficiency indicators as a result of:

  • the use of round cross-section fire tubes made of boiler steel, which makes it possible to reduce the flow rate of gas combustion products and ensure efficient heat transfer due to a longer stay of combustion products in the heat exchanger.
  • the use of semi-sector spiral turbulators, which increase the efficiency of heat transfer from hot gas combustion products to water in the boiler by creating special rotating turbulent gas flows inside the fire tubes.
  • applications of stainless steel tubular burners from the best company in Europe for the production of gas burners Polidoro. The torch-forming field has slots 0.6 mm wide, which ensures high-quality mixing of gas with air and makes it possible to obtain uniform carpet combustion in the furnace.
  • carefully experimentally selected height of the combustion chamber provides the required quality of the gas-air mixture for its complete combustion without the formation of harmful emissions of carbon and nitrogen oxides.
  • a long copper coil allows you to better warm up the water due to the increased heat exchange area.

Corrosion protection. Durability.

Boiler steel heat exchangers are coated outside and inside with heat-resistant paint. This provides increased resistance to corrosion and the effects of operational factors.

The heat exchanger is designed to operate under a pressure of 3.0 atm. The tightness test is carried out with a pressure of 4.5 atm. The safety margin of the heat exchanger before rupture is 9.0 Atm.
The design of the heat exchanger is reinforced along the perimeter with welded channels
which provides additional structural rigidity, resistance to variable pressure in the heating system, as well as to temperature loads during heating and cooling of the heat exchanger during operation. Seamless fire tubes made of boiler steel reduced the number of welds in the heat exchanger and eliminated the possibility of leakage inside it during operation.

Special boiler steel is a guarantee of high performance of the ROSS boiler

No condensation! Extended heat exchanger service life up to 25 years

The entire height of the combustion chamber is covered by a water jacket, into which water is supplied from the return line of the heating system. The walls of the combustion chamber, due to infrared radiation from the burner torch, take away heat, due to which the water is heated in this area. Upon reaching the upper part of the furnace and the pipe part of the heat exchanger, the water temperature rises to 50-60 ° C, which prevents the formation of condensate from the combustion products inside the chimneys.

Adjustable traction gap.

Unlike other manufacturers, the operability of the ROSS boiler is ensured at a chimney height of 1.5 meters or more.

The chimney can be connected vertically or horizontally. When connecting boilers to existing chimneys, it is often necessary to adjust the draft to ensure optimal operation. In ROSS boilers, unlike other manufacturers, an adjustable draft break is used. The design of the boiler makes it possible to ensure stable operation of the boiler in a wide range of chimney draft values.

Saving gas - 100 m? in year. Some models of boilers are equipped with direct ignition, i.e. there is no constantly burning igniter. This leads to a decrease in gas consumption by 100 m? in year.

In boilers with direct ignition, the control of the gas burner device is carried out from the controller, which allows you to control the operation of the boiler from the room thermostat of the programmer, carry out weather-dependent control, providing additional gas savings, as well as organize a hot water supply system using an indirect heating boiler, connect a turbo attachment for the forced removal of combustion products from the boiler.

The temperature of the outer surfaces of the boiler does not exceed 40 degrees Celsius
A 20 mm layer of insulation minimizes heat loss from the combustion chamber and prevents heating of the outer walls of the boiler. As a heater, Nobasil foil is used, certified for use in residential premises.

Quality control

After each technological operation, each boiler and its elements undergo 100% quality control:

  • Checking the tightness of the heat exchanger and the DHW circuit by pressure testing with water at a pressure of 1.5 times the maximum allowable, that is, 4.5 atm. and 9.0 atm. respectively. In this case, the heat exchanger should not only not leak, but also should not be deformed.
  • Tightness of gas communications.
  • Checking and adjusting gas automation individually for each product.
  • Checking the operation of the boiler safety systems in case of overheating of the coolant, in the absence of draft in the chimney, in the event of a short-term interruption of the gas supply.
  • overall performance of the boiler.
Model/Article 50/100160



Heated area, m 2, no more 500
Rated thermal power, kW 48
Pressure in the heating circuit, MPa, no more 0,3
Efficiency,%, not less 93
Vacuum in the chimney, Pa, not less than 4
Gas consumption at rated thermal power, m 3 / hour
- for natural gas, m 3 / hour 5,8
- for liquefied gas, kg/h 4,4
Number of burners 5
The volume of water in the heat exchanger, dm 3 (l), not less than *** 34
Water consumption for hot water supply at? T=30 °С, l/min** 9
Chimney diameter, mm, not less than 180
Nozzle hole diameter, mm, no more
- for natural gas 3
- for liquefied gas 2,3
Connecting thread of branch pipes, inch
- for connection to the heating system G3
- for gas supply G 3/5
- for hot water circuit G 1/3
Overall dimensions, mm, no more
- length 605
- width 680
- height 880
Weight, kg, max*** 148

1. Pickup

Using this service is very easy. When making a purchase, indicate the nearest point of issue of goods as the delivery address. As soon as the order arrives, you will be notified. You can pick it up at any time, taking into account the opening hours of the pickup point. On the spot you can check whether the tool was damaged during transportation and whether all the elements of its configuration are available.

2. Delivery to the place of residence

The delivery service of the Trading House company delivers purchases purchased in the company's stores, as well as when buying through the website and ordering by phone 30-03-04.

Delivery orders are accepted daily from 9 to 18, except Sunday, in three ways:

  • the seller, when making a purchase in the store;
  • through the website by placing an order;
  • operator, when ordering by phone 30-03-04.

Delivery is carried out with a one-time order in the amount of at least 1000 rubles.

Peculiarities

Heating area 500 m²
Power 50 kW
Efficiency 93%
Maximum water heating temperature 90 °С
Nominal gas pressure 1274 Pa
Type of heat exchanger Steel welded tubular
Automation NOVA 820
Pressure in the circuit, not more than 0.3 Pa
Vacuum in the chimney, not less than 4 Pa
Gas consumption at normal heat output 5.8 m³/h
The volume of water in the heat exchanger is 38 liters.
Water consumption for hot water at ΔT - 30 ° C --- l.
Weight 130 kg

Floor standing gas boiler ROSS AOGV-50 lux Designed for heating rooms equipped with a chimney. A wide range of models of this series allows you to choose an AOGV-boiler that best meets the requirements of the buyer, which in turn ensures the most efficient and economical operation of the heating system. Double-circuit models provide heating of water for domestic needs. All models are available with both vertical and horizontal chimney outlets.

Peculiarities:

  • the use of round cross-section fire tubes made of boiler steel, which makes it possible to reduce the flow rate of gas combustion products and ensure efficient heat transfer due to a longer stay of combustion products in the heat exchanger.
  • the use of semi-sector spiral turbulators, which increase the efficiency of heat transfer from hot gas combustion products to water in the boiler by creating special rotating turbulent gas flows inside the fire tubes.
  • applications of stainless steel tubular burners from the best company in Europe for the production of gas burners Polidoro. The torch-forming field has slots 0.6 mm wide, which ensures high-quality mixing of gas with air and makes it possible to obtain uniform carpet combustion in the furnace.
  • carefully experimentally selected height of the combustion chamber provides the required quality of the gas-air mixture for its complete combustion without the formation of harmful emissions of carbon and nitrogen oxides.
  • a long copper coil allows you to better warm up the water due to the increased heat exchange area.
Specifications
BrandRoss
Assembly countryUkraine
Boiler typegas
Number of circuits single-loop
The combustion chamberopen
Type of fuelLPG, Natural gas
Installationfloor
Heated area 480 sq. m.
Power50 kW
efficiency %93
Controlmechanical
Manufacturer country Ukraine
non-volatile Yes
Primary heat exchanger material steel
Consumption of liquefied gas, kg/hour 4.4
Consumption of natural gas cube. m/hour 5.8
Hot water capacity at t 30°C, l/min 9
Max. water pressure in the heating circuit, bar 3
Colour white
Comfort
Functionsthermometer
Peculiaritiesexternal control connection
Connection and overall dimensions
Overall dimension 680×880×605mm
Chimney diameter 180 mm
The weight148 kg
Branch pipe for connecting the DHW circuit 1/2"
Heating circuit connection 2"
Gas connection 3/4"

Floor standing gas boiler ROSS AOGV 50 luxury reviews

AOGV-boilers ROSS "Lux" designed for heating rooms equipped with a chimney. Double-circuit models provide heating of water for domestic needs. All models are available with both vertical and horizontal chimney outlets.

Advantages of AOGV-boilers ROSS of the Lux class: Profitable -high efficiency - 92%.

We achieved high efficiency indicators as a result of:

  • the use of round cross-section fire tubes made of boiler steel, which makes it possible to reduce the flow rate of gas combustion products and ensure efficient heat transfer due to a longer stay of combustion products in the heat exchanger.
  • the use of semi-sector spiral turbulators, which increase the efficiency of heat transfer from hot gas combustion products to water in the boiler by creating special rotating turbulent gas flows inside the fire tubes.
  • applications of stainless steel tubular burners from the best company in Europe for the production of gas burners Polidoro. The torch-forming field has slots 0.6 mm wide, which ensures high-quality mixing of gas with air and makes it possible to obtain uniform carpet combustion in the furnace.
  • carefully experimentally selected height of the combustion chamber provides the required quality of the gas-air mixture for its complete combustion without the formation of harmful emissions of carbon and nitrogen oxides.
  • a long copper coil allows you to better warm up the water due to the increased heat exchange area.

Corrosion protection. Durability.

Boiler steel heat exchangers are coated outside and inside with heat-resistant paint. This provides increased resistance to corrosion and the effects of operational factors.

The heat exchanger is designed to operate under a pressure of 3.0 atm. The tightness test is carried out with a pressure of 4.5 atm. The safety margin of the heat exchanger before rupture is 9.0 Atm.
The design of the heat exchanger is reinforced along the perimeter with welded channels
which provides additional structural rigidity, resistance to variable pressure in the heating system, as well as to temperature loads during heating and cooling of the heat exchanger during operation. Seamless fire tubes made of boiler steel reduced the number of welds in the heat exchanger and eliminated the possibility of leakage inside it during operation.

Special boiler steel is a guarantee of high performance of the ROSS boiler Without condensate! Extended heat exchanger service life up to 25 years

The entire height of the combustion chamber is covered by a water jacket, into which water is supplied from the return line of the heating system. The walls of the combustion chamber, due to infrared radiation from the burner torch, take away heat, due to which the water is heated in this area. Upon reaching the upper part of the furnace and the pipe part of the heat exchanger, the water temperature rises to 50-60 ° C, which prevents the formation of condensate from the combustion products inside the chimneys.

Adjustable traction gap.

Unlike other manufacturers, the operability of the ROSS boiler is ensured at a chimney height of 1.5 meters or more.

The chimney can be connected vertically or horizontally. When connecting boilers to existing chimneys, it is often necessary to adjust the draft to ensure optimal operation. In ROSS boilers, unlike other manufacturers, an adjustable draft break is used. The design of the boiler makes it possible to ensure stable operation of the boiler in a wide range of chimney draft values.

Saving gas - 100 m³ per year. Some models of boilers are equipped with direct ignition, i.e. there is no constantly burning igniter. This leads to a reduction in gas consumption by 100 m³ per year.

In boilers with direct ignition, the control of the gas burner device is carried out from the controller, which allows you to control the operation of the boiler from the room thermostat of the programmer, carry out weather-dependent control, providing additional gas savings, as well as organize a hot water supply system using an indirect heating boiler, connect a turbo attachment for the forced removal of combustion products from the boiler.

The temperature of the outer surfaces of the boiler does not exceed 40 ºС
A 20 mm layer of insulation minimizes heat loss from the combustion chamber and prevents heating of the outer walls of the boiler. As a heater, Nobasil foil is used, certified for use in residential premises.

Quality control

After each technological operation, each boiler and its elements undergo 100% quality control:

  • Checking the tightness of the heat exchanger and the DHW circuit by pressure testing with water at a pressure of 1.5 times the maximum allowable, that is, 4.5 atm. and 9.0 atm. respectively. In this case, the heat exchanger should not only not leak, but also should not be deformed.
  • Tightness of gas communications.
  • Checking and adjusting gas automation individually for each product.
  • Checking the operation of the boiler safety systems in case of overheating of the coolant, in the absence of draft in the chimney, in the event of a short-term interruption of the gas supply.
  • overall performance of the boiler.

Technical characteristics of luxury floor standing gas boilers

Model/ vendor code 40/100148
40D/ 100149
50/100160
50D/ 100161
50R/ 100154
50RD/ 100155
70/100168
70D/ 100169
70R/ 100164
70RD/ 100165
96/100175
96D/ 100176
96Р/ 100177
96RD/ 100178
1 Heated area, m 2, no more 400 500 700 960
2 Rated thermal power, kW 40 48 70 96
3 Pressure in the heating circuit, MPa, no more 0,3
4 Efficiency,%, not less 93
5 Vacuum in the chimney, Pa, not less than 4,0
6 Gas consumption at rated thermal power, m 3 / hour
- for natural gas, m 3 / hour 4,6 5,8 8,0 10,8
- for liquefied gas, kg/h 3,5 4,4 6,2 8,4
7 Number of burners 4 5 4 6
8 The volume of water in the heat exchanger, dm 3 (l), not less than *** 32(28) 38(34) 50(46) 61(56)
9 Water consumption for hot water supply at T=30 °С, l/min** 7,5 9 12 18
10 Chimney diameter, mm, not less than 150 180 180 230
11 Nozzle hole diameter, mm, no more
- for natural gas 3 3,8 3,5
- for liquefied gas 2,3 2,9 2,7
12 Connecting thread of branch pipes, inch
- for connection to the heating system G2 DU-70 DU-70
- for gas supply G 3/4 G1
- for hot water circuit G 1/2
13 Overall dimensions, mm, no more
- length 605 770 840
- width 600 680 680 805
- height 880
14 Weight, kg, max*** 125(132) 142 (148)
138* (146*)
180 (190)
187* (195*)
227 (235)
227* (236*)

D - double-circuit
R - boilers with direct ignition, volatile (connection to a 220V network)
* - characteristics of volatile boilers
** - with the heating system turned off and the maximum boiler power