Teplopribor group of companies (GC) (Teplopribor, Prompribor, Teplokontrol, etc.)- these are devices and automation for measuring, controlling and regulating the parameters of technological processes (flow metering, heat control, heat accounting, control of pressure, level, properties and concentration, etc.).

At the price of the manufacturer, products are shipped both of our own production and of our partners - leading factories - manufacturers of instrumentation and automation, control equipment, systems and equipment for controlling technological processes - process control systems (much is available in stock or can be manufactured and shipped as soon as possible) .

Flow meters-meters ESKO-RV.08, ESKO-R electromagnetic

Electromagnetic flowmeters-meters ESKO-RV.08, electromagnetic digital ESKO-R designed for continuous measurement of volumetric flow rates or volumes of drinking, technical, heating water and steam condensate in water and heat supply systems, as well as other electrically conductive liquids in pipelines with a nominal diameter of DN from 15 to 300 mm, both in forward and reverse ( reverse) direction.

Digital electromagnetic flowmeter ESKO-R is distinguished by the presence RS485 interface and improved performance in a number of ways.

can be used at enterprises of energy, industry, utilities and agriculture for commercial accounting of water (water consumption), as part of heat meters, in sewerage, in data collection systems, monitoring and control of technological processes.

Flowmeters ESKO-RV.08, ESKO-R are used both as part of heat meters, and independently at heat power, industrial and domestic water metering facilities.

The cost of the flowmeter ESKO-RV.08, ESKO-R depends on the model, DN, execution, total order volume and other pricing factors (see order forms for flowmeters, how to choose, order, buy).
The price of the flowmeter ESKO-RV.08 (basic version) - from 11,500 rubles.
The price of the flow meter ESKO-RV.08 is indicated without VAT, specific conditions and prices, how to order (buy), as well as the availability of flow transducers ESKO-R (B) in stock (or the production time) check with the sales managers by e-mail and phone , specified in the Contacts section of the site.

Flowmeter-meter ESKO-RV.08 electromagnetic

Flowmeter-meter ESKO-RV.08 electromagnetic consists of a full-bore electromagnetic primary flow converter (PPR) and a measuring unit (IB), combined into a monoblock.

Flowmeters ESKO-RV.08 are available in designs which are different:
According to the design of the PPR:
- PPR with flange connection (basic version);
- PPR with flangeless (bayonet or threaded) connection (optional).
According to the design of IS:
- IS without display (basic version);
- IB with remote display (optional).

The principle of operation of the e / m flowmeter ESKO-RV.08 based on the phenomenon of electromagnetic induction. When passing through an electrically conductive
liquid through a magnetic field with magnetic induction B, in it, as in a moving conductor, an electromotive force EMF proportional to the velocity of the liquid is induced.
EMF is removed by two electrodes located diametrically opposite in one cross section of the PPR pipe.
The signal from the PPR is fed by shielded wires to the input of the IB, which provides its further processing.
The EMF value does not depend on the temperature, viscosity and conductivity of the liquid, provided that the conductivity is in the range from 10-3 to 10 S/m at a temperature of 0 to +150°C and a pressure of 0.1 to 2.5 MPa.

Operating conditions and parameters of the working environment of the flowmeter ESKO-RV.08

The degree of protection of flowmeters from environmental influences according to GOST 14254 is not lower than IP54.

Measured medium - liquid with electrical conductivity from 10-3 to 10 S/m at temperature from 0 to +150°C and pressure from 0.1 to 2.5 MPa.

Calibration interval (MPI) - 4 years.

Functionality of ESKO-RV.08 flowmeters

Flow meters ESKO-RV.08 provide measurement, accumulation, storage and output to external devices of the following data:

— current values ​​of volumetric water flow;

— total (cumulative) volume of water;

— setup parameters and instrument status.

With a display, the data can be displayed directly.

Main technical characteristics of the electromagnetic flowmeter-meter ESKO-RV.08

Parameter (characteristic) of the electromagnetic flowmeter-counter ESKO-RV.08
Working mode continuous
Power, V / Hz (~36±10%)/(50±1)
Maximum power consumption, W 7
Working overpressure of the measured medium, MPa 1,6 (2,5)
Length of straight pipeline sections, Du 3 before and 1 after
Service life, years 12
Time to failure, hours 20000
Warranty period, months 18
Time of saving information in non-volatile memory, not less than, years 10

The largest and smallest flow rates of the heat carrier of the ESKO-RV.08 flow meter

Flowmeter outputs ESKO-RV-08

Flow meters ESKO-RV-08 have two frequency-pulse outputs: direct and inverse. If the flow meter is measuring volume flow
(volume) in the forward direction, then the frequency or pulse train is applied to the direct output. Otherwise, on
inverse output. Frequency-pulse outputs are passive output circuits, which are optocouplers with transistor
exit keys.

Designation record form when ordering flowmeter ESKO-RV.08

When placing an order for the flowmeter ESKO-RV.08

Flowmeter-counter ESKO-R digital electromagnetic with RS485 interface

Flowmeter-counter ESKO-R digital electromagnetic designed for continuous measurement of volumetric flow rates and volumes of liquid electrically conductive media. ESKO-R flowmeters allow measuring the flow and volume of liquid both in the forward and in the reverse (reverse) direction.

Flowmeter ESKO-R is a component product, and includes:
- primary flow converter - electromagnetic and computational-measuring unit (CME), combined into a monoblock;
- overpressure sensors (may not be used);
- resistance thermocouples (may not be used).

The principle of operation of electromagnetic flowmeters ESKO-R is based on the phenomenon of electromotive force (EMF) induction in a moving magnetic field conductor - the medium being measured. The induced EMF, the value of which is proportional to the flow rate of the medium being measured, is perceived by the electrodes and enters the computing and measuring unit (CMU), which performs signal processing, calculation of volume flow and volume and converts it into standardized analog and digital output signals. The BVI of the ESKO-R flowmeter has two inputs for connecting resistance thermocouples (sets of resistance thermocouples with nominal static conversion characteristics (NSKh 100P, 500P, 1000P, Pt100, Pt500, Pt1000) and two inputs of the "current loop" standard with a shifted range from 4 to 20 mA for overpressure sensors The results of measurements of temperature and overpressure of the coolant are formed in the BVI in the form of a digital output signal.

To connect to a power source and recording devices, ESKO-R flowmeters can have one, two four-pin din connectors or one four- and one three-pin din connector, depending on the availability of enabled communication interfaces.

Functionality, features and advantages of the ESKO-R digital flowmeter:

— RS-485 interface, which allows you to connect flowmeters into a network in order to transmit information about the results of measurements by means of a digital (discrete) coded signal;

- the event log;

— especially precise executions;

— increased average service life and time between failures;

- Possibility of direct current supply 24 V;

- Warranty period - 18 months.

Output signals and presentation of measurements of the ESKO-R flowmeter

Flowmeters ESKO-R provide the presentation of measurement results in the following form:

- output frequency signal of a rectangular shape with a programmable frequency directly proportional to the flow rate;

- output pulse signal with a programmable weighting factor (l/imp);

— values ​​of volume flow, volume, temperature, excess pressure in the form of a digital coded signal;

— display on the display of the measured values ​​of volume flow, volume, temperature, overpressure (for version with display);

- RS-485 serial interface, which allows to connect flowmeters into a network via a half-duplex multipoint differential communication line of the "common bus" type in order to transmit information about the results of measurements of volumetric flow, volume, temperature, overpressure using a digital (discrete) coded signal;

— serial interface RS-232С, which is used by the manufacturer for technological purposes;

- frequency-pulse outputs - passive circuits, which are optocouplers with transistor switches at the output.

Main technical characteristics and metrological parameters of the ESKO-R flowmeter

Parameter (characteristic) of the ESKO-R flowmeter Parameter value (characteristics)
Temperature of measured medium, Tee, °C from 0 to +150
Measured medium pressure, no more than, MPa 1,6 – 2,5
Range of measured temperature differences, °C +3 to +147
The volume of the accumulated measured medium displayed on the LCD display, m3 0 to 1999999
AC Power Options
Voltage, V
36±3.6
DC Power Options
Voltage, V
20.4 to 28.8
Mean time between failures, not less than, hours 100000
Calibration interval (MPI), years 5
Average service life, years 15
Degree of dust and water protection IP65

Ranges and measurement error of electromagnetic flowmeter ESKO-R

Nominal diameter (DN) of the ESKO-R flowmeter, mm Minimum flow rate Gmin, m3/h Maximum consumption Gmax, m3/h
Execution
A B 1 2
15 0,00512 0,0128 0,0256 0,064 6,4
20 0,00912 0,0228 0,0456 0,114 11,4
25 0,0144 0,036 0,072 0,18 18
32 0,0232 0,058 0,116 0,29 29
40 0,036 0,09 0,18 0,45 45
50 0,056 0,14 0,28 0,7 70
65 0,0944 0,236 0,472 1,18 118
80 0,144 0,36 0,72 1,8 180
100 0,224 0,56 1,12 2,8 280
150 0,504 1,26 2,52 6,3 630
200 0,904 2,26 4,52 11,3 1130
300 2,032 5,08 10,16 25,4 2540
Limits of permissible relative error in measuring volume flow and volume depending on flow rates, %:
Execution group A

100≥D≥2.0
2.0≥D≥0.1
0.1≥D≥0.08
±0.5
±1.0
±3.0
Performance group B
Sub-range D measurement in % of Gmax
100≥D≥2.0
2.0≥D≥1.0
1.0≥D≥0.4
0.4≥D≥0.2
±0.5
±1.0
±1.5
±2.5
Performance group 1
Sub-range D measurement in % of Gmax
100≥D≥2
2≥D≥1
1≥D≥0.6
0.6≥D≥0.4
±1.0
±1.5
±2.0
±2.5
Performance group 2
Sub-range D measurement in % of Gmax
100≥D≥50
50≥D≥4
4≥D≥2
2≥D≥1
±1.5
±2.0
±2.5
±3.0
Limits of permissible absolute error when measuring the temperature of the coolant (without taking into account the absolute error
thermal converters, C
±(0.2+0.0005 t)
Limits of permissible absolute error when measuring the temperature difference of the coolant (without taking into account the absolute
errors of thermal converters), С
±(0.04+0.0005Δt)
Limits of permissible relative error in measuring the temperature difference (without taking into account the error of thermal converters), % ±(0.5+Δtmin /Δt)
Limits of permissible error reduced to the upper limit when measuring excess pressure in pipelines (without taking into account the error of the DID),% ±0.25
where t is the temperature of the working medium, C; Δtmin is the minimum temperature difference measured by the flow meter, С; Δt is the measured temperature difference, С.

Delivery package of the ESKO-R flowmeter

Name Symbol Quantity Note
Flowmeter-counter
electromagnetic
ESCO-R 1 PC. In accordance with
order
RTD or RTD kit Missing, 1
set or 1
PCS.
according to order
Excess sensor
pressure FID
According to the table below 0, 1 or 2 pcs. In accordance with
order
Mounting kit
parts (KMC)
1 PC. In accordance with
supply contract
Passport ESCO. 23367.024 PS 1 copy
Manual ESCO. 23367.024 RE 1 copy
Verification procedure MP 208-022-2018 1 copy per party

ESKO-R flowmeters can be equipped with platinum resistance thermometers (RTP) or RTD sets, as well as overpressure sensors (DID) according to the following tables.

Resistance thermometers, platinum Resistance thermometer kits
platinum
Type Number in the State Register Type Number in the State Register
TSP-N 38959-17 KTS-B 43096-15
TS-B 61801-15 KTPTR-01.03, 06,
07, 08
46156-10
TPT-1, 17, 19, 21, 25R 46155-10 KTPTR-04.05, 05/1 39145-08
TPT-7, 8, 11, 12, 13,
14, 15
39144-08 CTSP-N 38878-17
TSP 65539-16 TSP-K 65539-16

Designation notation form when ordering digital electromagnetic flowmeter ESKO-R

When placing an order for a digital electromagnetic flowmeter ESKO-R you should be guided by the above technical characteristics of the device, and also adhere to the established form (structure) of the designation when ordering:

On a separate order, additional equipment for electromagnetic (meters) liquids - KMC, equipment and dispatching systems, etc. can be purchased. etc. (see below for detailed information on additional equipment for e / m flow sensors - water meters).

Possible errors when placing an order for flow meters - hot and cold water meters ESKO-R (ESKOR)

When ordering electromagnetic flow meters - hot and cold water meters ESKO-R, we recommend that you be careful when placing an order, incl. take into account the possible variants of the designation and the errors encountered when ordering. For example, we have encountered such errors in applications:
- incorrect or incorrect name of the device: inductive water meter, e / m water meter, electromagnetic flow meter, induction flow meter, water meter, flow sensor, flow converter, flowmeter, flowmeter and other errors in the name of the device ..
- incorrect model designations and spelling errors: ESKOR, ESKO-R (letter E instead of E), ESKOER, ESK-R, ESK-R, ESKO-P, ECKO-P (in Latin instead of Cyrillic), etc.
- spelling errors related to translation, transliteration or keyboard layout, for example: electromagnetic flow meter ESKO-R, digital electromagnetic flow converter ECKO-P, "CRJ-H, ‘crk-h (in En-layout), etc. etc.

Therefore, we kindly ask you to be careful when placing an order for electronic digital water meters ESKO-R, do not confuse the designations, and if you do not know or are not sure, then simply write the main technical characteristics (DN, temperature of the measured medium, connection method, etc. ) and operating conditions in a simple form of presentation, and the engineers of our company will select the device you need and add. equipment at the best ratio Price - Quality - Production time (availability in stock).

Technical documentation for electromagnetic flow meters-meters ESKO-RV.08, ESKO-R:
see Order card ESKO-RV.08, ESKO-R electromagnetic flowmeters (download the questionnaire).
see Technical characteristics of ESKO-RV.08, ESKO-R electromagnetic flowmeters (Technical description).
see Operation manual ESKO-RV.08, ESKO-R electromagnetic flowmeters.
see Method of verification ESKO-RV.08, ESKO-R electromagnetic flowmeters.
At the request of the consumer, an order card (form) (questionnaire), a certificate / certificate of approval of the type of measuring instrument, permissions for use, a declaration of conformity, a passport, a technical description and an operating manual, an additional user manual can be sent. equipment and peripheral devices, a description of the type of measuring instrument and a verification procedure, as well as other permits and regulatory documents (GOSTs, SanPiN, SNiPs and accounting rules, etc.).

Additional information about electromagnetic flow transducers (flowmeters)

KMCH and additional equipment for electromagnetic flow meters (water meters)

The complete set and types of sets of mounting parts (KMCH) and additional equipment are selected depending on the type of flowmeter:
— apartment meters (household/individual DN15, DN20);
- house meters (general house Du25,32,40,40);
– industrial (DN over 50mm);
see the nomenclature, prices and technical descriptions of liquid flow meters (water meters).
see accessories and valves for flowmeters .

Household and industrial flow meters can have quite a complex and varied configuration:

Connecting fittings:
Sets of mounting parts - KMC DN15-250mm for threaded (coupling), flanged or "Sandwich" type connection (wafer).
(counter flanges, gaskets, bolts/studs, nuts, washers) for installing a meter (flow meter) or spacer (dimensional simulator):
Counter flange kits("KOF" according to GOST 12820-80, etc.)
Transitions Du, straight sections (connecting sections) and other elements of the pipeline and welded parts.
Spacers(dimensional simulators, mounting inserts).
Protective equalizing conductor with attachment kit.
Seals and fasteners(gaskets, bolts (studs), nuts, washers)
It is also possible to supply complete mounting water metering units: flanged and interflange-“sandwich” (metering units for cold (UUHVS) and hot (UUGVS) water supply, which include devices, straight sections, KMC, ball valves, etc.).

Additional equipment of flow metering units (UUR):
Mounting and shutoff valves: taps, valves, connecting fittings, tees, drains
Mounting instrument cabinets
I&C: calculators, manometers, thermometers, sensors, relays, temperature and pressure transducers, regulators, power supply units (sources), control units.
Equipment and systems for dispatching
Peripheral devices for data collection and transmission: modules (M-Bas, pulse, etc.), radio modules, hubs, GSM/GPRS modems, antennas, adapters, converter, interface converters, software (dispatching programs for data reading), indicators, recorders, archivers , computers and other equipment.
Cable (power supply and communication (signal).

General recommendations for the placement, installation and operation of electromagnetic and other flow meters (water meters)

Flowmeters usually designed for installation in heated rooms or special pavilions with a positive ambient temperature Toc (air) usually from 0 to +50C and relative humidity not more than 80%. The instruments must be freely accessible for inspection at any time of the year. The place of installation must guarantee the operation of the device without possible mechanical damage. Installation of water meters in flooded, cold rooms at temperatures below 5C, and in rooms with humidity over 80% is not recommended (except for special versions: for negative temperatures or "flooded" version for flow converters with dust and water protection code IP68).

When installing an electromagnetic flow meter, the following mandatory conditions must be met:

b) Installation is carried out in such a way that the device is always filled with water(installation in a pressure pipeline);

c) Requirements for straight sections for an electromagnetic flowmeter:
When installing the device after bends, shutoff valves, adapters, filters and other devices that create flow distortion, it is necessary to provide for a straight section of pipelines for straightening the flow from 2 to 5DN long(depending on the type of hydraulic resistance preceding it - see the figure (confuser, valve, outlet, filter, sump, valve, pump, etc.)), and behind the device - at least 2Du (where Du is the conditional diameter of the pipeline). It should be taken into account that if the installation conditions are violated, an additional measurement error appears.

d) In case of repair or replacement of the water flow meter before the direct section upstream of the device and after the direct section of the pipeline after the device shut-off valves (faucets, valves, gate valves, valves) are installed, as well as drains / drains for emptying the disconnected section, which are mounted outside the area of ​​\u200b\u200bstraight sections.

e) Before the device, but after the shut-off valves outside the area of ​​the straight section of the pipeline; as well as after the meter when installing it on the return pipeline of the hot water supply or heating system (heat supply), to the shutoff valves it is recommended to install water filters(straight or oblique coarse mesh filters).

f) It is not allowed to install an electromagnetic flow meter at a distance of less than 2 meters from devices that create a powerful electromagnetic field around them (for example, power transformers and cables), as well as placing the device in the area of ​​​​permanent magnets or getting the pipeline under voltage.

We will be glad if the above information was useful to you, and we also thank you in advance for contacting any of the representative offices of the Teplopribor group of companies (three Teplopribor, Teplokontrol, Prompribor and other enterprises) and promise to make every effort to justify your trust.

Electromagnetic flow meters ESKO RV.08

The product is registered in the State Register under the number 28868-05

PURPOSE AND FIELDS OF APPLICATION

Flow meters - electromagnetic meters ESKO RV.08 (hereinafter referred to as flow meters) are designed for continuous measurement of volume flow and volume of hot and cold water, as well as other liquid electrically conductive media.

Scope: water and heat supply systems, systems for commercial water metering as part of heat meters, in sewerage, systems for collecting data, monitoring and regulating technological processes at energy, utilities and agriculture enterprises.

DESCRIPTION

The principle of operation of the flowmeter is based on the phenomenon of electromagnetic induction: when an electrically conductive liquid passes through a magnetic field, an electromotive force (EMF) is induced in it, as in a moving conductor, proportional to the average velocity of the liquid in the pipe section. The EMF value does not depend on the temperature, viscosity and conductivity of the liquid.

The flow meter consists of a full-bore electromagnetic primary flow converter (PPR), a measuring unit (IB), made as a monoblock. The IB may have a display that provides the possibility of visual reading of the measurement information.

Flowmeters are available in versions that differ:

according to the design of the PPR - with flange connection, flangeless (on request - with bayonet or threaded) connection;

by the presence of a display - without a display (basic), with a display.

MAIN SPECIFICATIONS

Nominal diameter 32 40 50 80 100 150 200 300

passage, mm

Maximum dimension 45 70 180 280 630 ISO 2540

consumption Gmax, M / h

limits of permissible basic relative error in measuring volume and volume flow, %:
performance group A
subrange D measurement in % of Gmax
2.0 D 0.4

0.4>D>0.25 0.25>D 0.2

performance group B subrange D measurements in % of G, 100>D>5 D>1 D>0.5 0.5>D>0.4

performance group C subrange D measurements in % of G,

100>D>50 50 D>2 2>D>1

Measured medium temperature range, "" С

Measured medium pressure, no more than, MPa
Electric water content of the medium, not less than, S/m

Temperature range of the ambient air, °С: for the primary converter for the measuring unit

AC supply voltage, frequency 50 Hz, V
Presentation of information:
- output unified frequency (frequency-pulse) electrical signal with a programmable pulse weight and a frequency proportional to the flow rate, Hz

Coded eleggric signal in the serial interface

- display on the display of measured values ​​of volume and volume flow.

Overall dimensions, not more than, mm height length

±1.0 ±1.5 ±2.0 ±2.5

±1.0 ±1.5 ±2.0

±1.5 ±2.0

2,5

0,02

-30 ... +50

5 ...+50 36±3.6

About - 10000 (on request)

RS485; RS232; "current loop"; ISO 11898 (by request)

240 ... 600 150 ... 500

width 95 ...485

Weight no more than, kg 5 ... 161

Mean time between failures, hour 28000

Full average service life, years 12

COMPLETENESS

The delivery set includes: - electromagnetic flowmeter-meter ESKO RV.08, TU 4213-001-73819860-2004;

Set of mounting parts;

Operation manual ABNR 407112.001 RE;

Passport ABNR 407112.001 PS.

VERIFICATION

The flow meter-meter is verified according to the procedure described in the "Verification" section of the Operation Manual, agreed with the SSC SI "NIITeplopribor". During verification, the following measuring instruments are used:

Megaohmmeter M4100/3, resistance up to 500 MΩ, voltage 500 V, GOST 23706; - electronic counting frequency meter 43-64, DLI2,721.006 TO; - flow meter type UROKS-400, error ±0.15%. Calibration interval - 3 years.

REGULATIONS AND TECHNICAL DOCUMENTS

GOST 28723-09 High-speed, electromagnetic and vortex flowmeters. General technical requirements and test methods.

GOST 12997-84 GSP products. General specifications.

TU 4213 - 001 - 73819860 - 2004 Flow meters-meters ESKO RV.08. Specifications

CONCLUSION

Type of electromagnetic flow meter ESKO RV.08 is approved with the technical and metrological characteristics given in the present description of the type, metrologically ensured upon release from production and in operation according to the state verification scheme.